Leuze electronic AMS 301i Manual page 15

Optical laser measurement system
Table of Contents

Advertisement

Inputs/outputs
Mechanical data
Housing
Optics
Weight
Protection class
Environmental conditions
Operating temperature
without device heating
with device heating
Storage temperature
Air humidity
Mechanical/electrical loading capacity
Vibrations
Noise
Shock
EMC
1)
Statistical error: 1 sigma; minimum switch-on time: 2 min.
2)
For UL applications: only for use in "Class 2" circuits acc. to NEC.
3)
Switching off the laser diode during system downtime can considerably extend the life expectancy of
the device. The laser life expectancy is calculated using a failure rate of 1%.
4)
With screwed-on M 12 plugs or mounted caps.
5)
With devices with heating, the switch on/off area of the internal heating can be extended to prevent
condensation from forming. A 100% prevention of the formation of condensation cannot be
guaranteed due to the limited heating capacity of the AMS 301i.
6)
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the operator may be required to take adequate measures.
Leuze electronic
Quantity
Input
Output
2, programmable
protected against polarity reversal
max. 60 mA, short-circuit proof
cast zinc and aluminum
glass
approx. 2.45 kg
IP 65 acc. to EN 60529
-5 °C ... +50 °C
-30 °C ... +50 °C
-30 °C ... +70 °C
max. 90 % rel. humidity, non-condensing
acc. to EN 60068-2-6
acc. to EN 60060-2-64
acc. to EN 60068-2-27
acc. to EN 61000-6-2 and EN 61000-6-4
AMS
301i
Specifications
4)
5)
6)
12