5.3
Mounting the AMS
General information
The two available deflector units are used for the 90 ° deflection of the laser beam,
see "Accessory deflector unit" on page 56.
Attention!
The deflector units are designed for a maximum range of 40 m.
Longer distances on request.
5.3.1

Mounting the laser beam deflector unit with integrated mounting bracket

The AMS
301i
can be mounted for three deflection directions:
1.
Upward beam deflection
2.
Beam deflection to the left
3.
Beam deflection to the right
The deflector unit is mounted on plane-parallel, flat walls or plant components. For error-
free position measurement, there must be an interruption-free line-of-sight between the
AMS 301i... and the deflection mirror as well as between the mirror and the reflector.
Use the M5 screws to mount the deflector unit. Secure the screws with a toothed lock
washer to protect against loosening caused by vibrations.
Figure 5.5:
Leuze electronic
301i
with laser beam deflector unit
is screwed onto the mechanism of the US AMS 01 deflector unit. The mirror
Mounting variants of the US AMS 01 laser beam deflector unit
i
AMS 301