Display and control panel AMS 301i
Notice!
The rear cover of this manual includes a fold-out page with the complete menu structure.
It describes the menu items in brief.
8.3.2

Parameter menu

Parameter handling submenu
The following functions can be called up in the Parameter handling submenu:
• Lock and enable parameter entry
• Set up a password
• Reset the AMS
Table 8.1:
Level 3
Parameter
enabling
Password
Parameters to
default
Additional important information on parameter handling can be found at the end of the
chapter.
RS 485 submenu
Table 8.2:
Level 3
Activation
Address
Baud rate
Format
41
301i
to default settings.
Parameter handling submenu
Level 4
Level 5
Selection/configuration option
Description
ON / OFF
The standard setting (OFF) prevents unintended parameter changes.
With parameter enabling activated (ON), the display is inverted. In this
state, it is possible to change parameters manually.
Activate
ON / OFF
password
To enter a password, parameter enabling must be activated.
If a password is assigned, changes to the AMS 301 can only be made
after the password is entered.
The master password 2301 bridges the individually set password.
Password
Configuration option of a four-digit numerical password.
entry
By pressing the enter button
Parameters to default, all parameters are reset to their
standard settings without any further security prompts.
In this case, English is selected as the display language.
RS 485 submenu
Level 4
Level 5
Selection/configuration option
Description
Activates or deactivates the AMS 301 as an RS 485 participant.
Setting of the address used for host communication. The address range
spans from 0 to 15.
9.6 kbit/s / 19.2 kbit/s / 38.4 kbit/s / 57.6 kbit/s / 115.2 kbit/s
Selection of the baud rate for serial communication. It must be the same
at the transmission and reception sides to enable communication.
... 8,n,1 / ... 8,e,1 / ... 8,o,1
Selection of the data mode for serial communication. Designation is done
in number of data bits, parity (N=none, E=even, O=odd) and number of
stop bits. For example, "8N1" therefore means 8 data bits, no parity, 1
stop bit.
after selecting
i
AMS 301
Standard
OFF
OFF
Standard
ON
0
38.4 kbit/s
8,n,1
Leuze electronic