Board Programming; Connecting Multiple Bollards; J275 Ha 2K20 - FAAC J275 HA 2K20 Translation Of The Original Instructions

Table of Contents

Advertisement

5.4 BOARD PROGRAMMING

After connecting and switching on the power to the control board as
per the previous chapter, select the work pre-setting for the bollard
J275 HA 2K20 by performing the following operation:
1. Access level 1 programming by holding down the F button on the
board (1 9). The letters
dF
2. Release the F button and with the + + button, select the value
3. Press the F button and hold it down whilst simultaneously pressing
the - button to exit programming screen and save the changes
made.
4. Press the F button and hold it down, as well as pressing + for
around 10 seconds, until the display shows
5. Release the buttons, then press the F button scroll until you reach
b6
the
parameter
b6
Y
6. Set the value
=
!
b6
Y
Setting
=
causes the bollard to raise immediately when the
emergency input is activated.
7. Press the F button and hold it down whilst simultaneously pressing
the - button to exit programming screen and save the changes
made.
For further information on programming the board, please refer to the
relevant instructions.

J275 HA 2K20

will appear on the display.
01
 1 9

5.5 CONNECTING MULTIPLE BOLLARDS

Up to 3 bollards can be connected simultaneously to a single JE275
board. To connect them, follow the diagrams below.
05
M1
~
M2
~
M3
~
1
2
3
1 2 3
1 2 3
14
MOT2
COM
MOT1
FAN
COM
COM
LAMP
J2
GND
OUT 4
OUT 3
OUT 3
OUT 2
OUT 1
+24 V
+24 V
GND
GND
EMERGENCY
STOP
FSW
CLOSE
OPEN A
LOOP 2
LOOP 2
LOOP 1
LOOP 1
J1
J5
UPPER limit switch
J3
LOWER limit switch
2 0
532270 - Rev.A

Advertisement

Table of Contents
loading

Table of Contents