Terminal Board J2 (Outputs); Terminal Board J3 (External Flashing Lamp); Terminal Board J4 (Loop Detector); Connector J5 (Motor) - FAAC B680H Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

GND +24
J1
3 4 5 6 7 8 9 10 11
SAFE
RX CL
1
2
3
GND
4
+24
5
GND +24
J1
3 4 5 6 7 8 9 10 11
SAFE
RX CL
1
2
3
GND
4
+24
5
TX CL
GND
1
+24
2
J1
3 4 5 6 7 8 9 10 11

4.2 Terminal board J2 (outputs)

OUT 1 - Output 1 open-collector GND (terminal 13): The output
can be set in one of the functions described in the Advanced
Configuration (par. 6). The default value is
Maximum load: 24 VDC with 100 mA.
PAUSE.
OUT 2 - Output 2 open-collector GND (terminal 15): The output can
be set in one of the functions described in the Advanced Configuration
03
(par. 6). The default value is
24 VDC with 100 mA.
OUT 3 - Output 3 open-collector GND (terminal 17): The output can
be set in one of the functions described in the Advanced Configuration
19
(par. 6). The default value is
24 VDC with 100 mA.
OUT 4 - Relay output 4 (terminals 19, 20, 21): The output can be
set in one of the functions described in Advanced Configuration (par.
01
6). The default value is
- BEAM ILLUMINATION. Maximum load:
24 VDC with 800 mA.
TX CL
1
2
Fig. 24
TX CL
1
2
RX CL
1
2
3
4
5
Fig. 25
GND +24
Fig. 26
04
- Beam OPEN or in
- CLOSED BEAM. Maximum load:
- WARNING LAMP. Maximum load:
4.3 Terminal board J3 (external flashing lamp)
LAMP: to these terminals you can connect a 24VDC FAACLED
external flashing lamp. The integrated flashing traffic light must be
connected independently to connector J15.
The 24V FAACLIGHT with incandescent lamp cannot
be connected to the J3 connector

4.4 Terminal board J4 (loop detector)

LOOP 1: magnetic loop LOOP 1
(OPEN, terminals 24-25): for OPENING.
GND
LOOP 2: magnetic loop LOOP 2
+24
(SAFETY/CLOSE, terminals 26-27): for SAFETY/CLOSING.

4.5 Connector J5 (Motor)

Rapid connector for connecting the motor.

4.6 Connector J7 (Encoder)

The B680H barrier is equipped with a device for detecting the opening
angle/bar position to ensure greater anti-crushing safety thanks to
the possibility of reversing the direction of movement the moment in
which an obstacle is detected. This device interfaces with the board
through connector J7.

4.7 Connector J10 (Radio)

Used for the rapid connection of the RP / RP2 Receivers. If a
2-channel receiver is used, like the RP2, it will be possible to directly
GND
command automated system OPEN and CLOSE from a 2-channel
+24
radio control. If a 1-channel receiver is used, like the RP, it will only
be possible to command OPEN.
GND
+24
Boards should be inserted and removed ONLY after
having cut off electrical power

4.8 Connector J11 (Beam break-out sensor)

Designed for connecting the break-out sensor for the pivoting beam
(if present). The sensor is optional. If it is not present, do not remove
the installed jumper.

4.9 Connector J12 (Emergency battery)

This connector is for connecting a battery (optional) for ensuring
automated system operation in case of temporary cut off of the main
power supply.

4.10 Connector J13 (36VDC Power Supply)

This factory-wired connector powers the E680 board.
The terminal shown in Fig. 1 ref. a must be connected
to the system earth by the installer during the electrical
connection operations.
4.11 Connector J15 (flashing traffic light)
This connector is for connecting the flashing traffic light built into
the barrier head. The flashing traffic light visually signals barrier
movement and, if needed, can control access to the property using
the different light colors.