04. MAINTENANCE

05. PNEUMATIC SYSTEM

CAUTION! RISK OF INJURY!
Push the X-button at the machine head, the red light illuminates showing the active
"BLOCKED MODE", or turn the machine o before checking the pneumatic system.
Failure to comply produces a risk of injury in case of an unintentional machine
operation.
CHECKING THE MAINTENANCE UNIT:
Check water in pressure regulator:
» The water level shouldn'd rise to the level of the filter cartridge
After unscrewing the drain screw
7
tor
.
Clean filter cartridge:
» Dirt and condensation are seperated through the filter cartridge
» Disconnect the machine from the compressed air supply.
» Loosen the drain screw
There shouldn'd be any pressure in the machine pneumatic system.
» Unscrew the water seperator
» Unscrew the filter cartridge
Wash the filter shell and cartridge with cleaning fluid (no solvent) and blast clean.
» Re-assemble the maintenance unit.
Check for system leaks.
07/2018
32
VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
6
7
8
8
, the water will flow under pressure out of the water sepera-
8
.
7
.
6
.
6
.
6
.