ERROR CODE
DESCRIPTION
» STEPPING MOTOR ERROR
200
Stroke encoder
203
Stroke motor overcurrent
204
Stroke motor could not reach designated position
205, 206, 207, 209
Stroke encoder EEPROM init error
210
Stepper driver BC Init error
220
Stroke encoder timeout
290
Stepper driver BC software incompatible
300
Stitch length encoder
303
Stitch length motor overcurrent
Stitch length motor could not reach destinated
304
position
305, 306, 307, 309
Stitch length encoder EEPROM Init error
399
Stitch length and stroke connector interchanged
TensionB / Steppermotor - Post bed / Edge guide
403
height - X-Y overcurrent
TensionB / Steppermotor - Post bed / Edge guide
404
height - X-Y guide not connected
410
Stepper driver DE Init error
Post bed switch / Edge guide height Y-X guide
414
endposition not reached
Post bed switch / Edge guide height Y-X guide
424
endposition Switch
not connected or motor is blocked in Init position
490
Stepper driver DE software incompatible
07. ERROR CODES
SOLUTION
» Check connector and cable S1
» Replace motor
» Replace control box
» Check connector and cable S1
» Measure resistance of the coils
» Replace motor
» Replace control box
» Check if the stitch regulator can move easily
» Redo stroke zero wizard
» Check connector and cable S1
» Replace motor
» Replace control box
Apply latest software update. If a timeout during
update occurs, replace control box
Contact VETRON Support
Apply latest software update
» Check connector and cable S2
» Replace motor
» Replace control box
» Check connector and cable S2
» Measure the resistance of the coils
» Replace motor
» Replace control box
» Check if the stitch regulator can move easily
» Redo stitch length zero wizard
» Check connector and cable S2
» Replace motor
» Replace control box
Check if S1 and S2 are pluged in correctly.
Swap if wrong
» Check connector and cable S3
» Measure resistance of the coils
» Replace motor
» Replace control box
Apply latest software update. If a timeout during
update occurs, replace control box
» Check connector and cable of the end switch
» Check if the end position can be reached manually
» Measure end switch function
Apply latest software update