07. ERROR CODES

02. ERROR MESSAGES

-1-3
NOTE:
The error codes refer to the control box connections. Depending on the machine type and
optional accessories, di erent functions can be controlled. This has to be considered
during troubleshooting.
ERROR CODE
DESCRIPTION
» BUS ERROR
2
AC voltage is too high
3
AC voltage is too low
4
Bus voltage is too high
5
Bus voltage is too low
6
Discharge function error
7
Bus current too high
8
Bus voltage faulty
9
31V Overcurrent
10
Command bus hard fault
60
Right bobbin monitor not connected
61
Left bobbin monitor not connected
» SAFETY ERROR
0
Obstacle detected
1
Timeout reading foot height
5
Timeout on foot height correction
10
Distance magnet / sensor too high
99
Critical safety module error
» MAIN DRIVE ERROR
100
Main motor encoder error
101
Main drive current zero sample
103
Main drive overload
104
Main drive hold position overload
105
Main drive current sample
07/2018
68
VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
SOLUTION
Check supply voltage
Replace control box
Apply main drive overload condition procedure
Replace control box
» Check all 31V consumers and cables (Bobbin
winder, thread clamp, trimmer, pneumatic
value) for short circuit
» Replace control box
» Check cable and connector B1
» Replace control box
Check connection of bobbin thread monitor (Y1-A1)
Check connection of bobbin thread monitor (Y1-A2)
» Clear area under the foot.
» Avoid obstacles while foot is lowering
Contact VETRON Support
» Check connector and cable M2
» Replace main drive
» Replace control box
» Do not turn the machine with hand
after power on
» Replace control box
Apply main drive overload condition procedure
Disable hold torque, check if turning the machine
with the mechanical handwheel is smooth while
machine is initialized
Replace control box