Pneumatic Connection - VETRON 5064 Service Manual

Table of Contents

Advertisement

1
WARNING!
Danger by compressed air
Disconnect the machine from the electrical network before any adjustment work!
Risk of injury if the machine starts up unintentionally.
PRESSURE SETTING:
01. Connect the machine to the compressed air system.
02. The operating pressure at the filter control valve
03. The pressure of the anvil wheel on pressure control valve
CAUTION
The maximum pressure of the pressure control valve
Higher pressure can damage the welding unit.
08. ADJUSTMENT

06. PNEUMATIC CONNECTION

2
is 6 bar.
1
2
is factory set to 3.5 bar.
is 4 bar!
2
VETRON 5064 Welding Machine
02/2021
89