07. ERROR CODES
02. ERROR MESSAGES
-1-3
ERROR CODE
DESCRIPTION
503
Footlifter overcurrent
504
Footlifter not connected
603
TensionA overcurrent
604
TensionA not connected
610
Stepper driver FG Init error
690
Stepper driver FG software incompatible
703
Edge guide / Puller lift stepper overcurrent
704
Edge guide / Puller lift stepper not connected
Edge guide / Puller lift switch
714
endposition not reached
Edge guide / Puller lift switch
724
not connected or motor is blocked in init position
» HEAD PCB ERROR
800
Head PCB connection lost
805
Head PCB EEPROM error
810
Head PCB init error
890
Head PCB software incompatible
» FIRMWARE UPDATE ERROR
2004
no udisk
2008
no type info
07/2018
70
VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
SOLUTION
» Check connector and cable S4
» Measure resistance of the coils
» Replace motor
» Replace control box
» Check connector and cable S5
» Measure resistance of the coils
» Replace motor
» Replace control box
Apply latest software update. If a timeout during
update occurs, replace control box
Apply latest software update
» Check connector and cable S6
» Measure resistance of the coils
» Replace motor
» Replace control box
» Check connector and cable of the end switch
» Check if the end position can be reached manually
» Measure end switch function
Check connector and cable B1
Replace HeadPCB
Apply latest software update. If a timeout during
update occurs, replace Head PCB
Apply latest software update
Try another USB stick.
Only use USB sticks recommended by VETRON
» Check the folder structure on the USB stick
» Copy the firmware data to your USB stick again

Hide quick links: