Thresholds
Select the Settings tab from the top, then click Thresholds.
The Thresholds page configures the threshold values of specific equipment before events are recorded.
Ignition
•
Startup minimum ignition value: Select the minimum ignition value (in volts) to start NVR system. NVR system will power on
only if ignition power is greater than the configured ignition value.
Restrictions: Startup ignition value should be greater than shutdown ignition value.
•
Shutdown minimum ignition: Select the minimum ignition value (in volts) to shutdown NVR system. NVR system will power
down gracefully if ignition power is less than the configured ignition vale.
Restrictions: Shutdown ignition value should be less than startup ignition value.
Temperature
•
Max. temperature: Default maximum temperature threshold is 60°C.
Accelerometer
The NVR contains a 3-axis accelerometer. An event is triggered when RMS (root, mean, square) value of all the axes is greater than
specified.
•
RMS: Enter the RMS value which when exceeded triggers an event.
Restrictions: RMS value can be configured from 0.1g to 16g.
GPS
•
Speed: Enter the maximum speed value (in mph) that can be obtained by the vehicle before an event is triggered.
Restrictions: Speed value can be configured from 0mph to 100mph.
Internal UPS
•
Battery Percentage: Default threshold value for internal battery is 60%.
Click Save Changes to save changed entries.