3Rw5 Communication Module (Slot 1); Data Set 92: Communication Module Diagnostics (Slot 1) - Siemens PROFINET SIRIUS 3RW5 Equipment Manual

Soft starters and solid-state switching devices
Hide thumbs Also See for PROFINET SIRIUS 3RW5:
Table of Contents

Advertisement

Code
Command
51
Normal operation
52
Test mode
Supported by SIRIUS 3RW50 and 3RW52 soft starters
1)
Supported by SIRIUS 3RW55 soft starter
2)
Supported by SIRIUS 3RW55 Failsafe soft starter
3)
4)
3RW50 soft starter from firmware version V1.0 or 3RW52 soft starter from firmware version V2.0
3RW55 soft starter from firmware version V2.1
5)
3RW55 soft starter from firmware version V2.0
6)
A.4.4

3RW5 communication module (slot 1)

A.4.4.1

Data set 92: Communication module diagnostics (slot 1)

Only read (r) access to the communication module diagnostics is possible. The data set 92 of the
3RW5 communication module (slot 1) is supported only by the 3RW5 PROFINET High Feature
communication module.
Byte
Data format
0
Unsigned8
2
Unsigned8
4
Unsigned16
6
Unsigned16
Supported by SIRIUS 3RW50 soft starter
1)
Supported by SIRIUS 3RW52 soft starter
2)
3)
Supported by SIRIUS soft starter 3RW55 and 3RW55 Failsafe
Byte
Bit
Data format
10
0
Bool
4
Bool
12
0
Bool
1
Bool
2
Bool
3
Bool
16
0
Bool
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004
Meaning
Coordination
Slot number
Length of data structure
Start position
Communication module diagnostics
Bus error
Operation without PN control
FW update rejected
FW update active
FW update successful
FW update faulty
Webserver active
Appendix
A.4 Data sets
3RW5
50 /
55
55‑F
2)
3)
52
1)
w
4)
w
w
w
w
w
4)
3RW
50
52
55 /
1)
2)
55‑F
3)
x
x
x
x
x
x
x
x
x
x
x
x
3RW5
PN HF
1)
r
r
r
r
r
r
r
2), 3)
161

Advertisement

Table of Contents
loading

Table of Contents