Operating The Air Compressor - Vanair Air N Arc All-in-One Power Systems 300 Operations Manual & Parts List

Table of Contents

Advertisement

®
AIR N ARC
300 SERIES ALL-IN-ONE POWER SYSTEM
2. Turn the Generator switch on the control
panel to the ON position.
Only plug power cords into the generator
receptacles AFTER the engine is running
Be careful not to overload the rated
capacity of the generator - 6,800 watts
(28 amps @ 240V) continuous.
Combined output on all generator receptacles is limited
to the total rated generator capacity. For example; if
1,500 watts (12.5 amps) is being drawn on the 120V
duplex receptacle, only 3,700 watts (15.5 amps) is
available at the 240V receptacle. Reference Appendix
A, Section A.3, Wattage Requirements for Common
Receptacle Units, for general information on the power
requirements of common power tools, motors and
extension cords. If the equipment is not listed in Section
A.3, check the desired power tool, motor or extension
cord manufacturer's specifications.
If the thermal overload circuit breakers on the generator
are tripped due to an overload condition, press the white
reset buttons on the generator panel to reset the
breakers (Figure 5-4).
If one of the generator circuit breakers is
tripped, the cause of the overload must
be determined before the circuit breaker
is reset and work is resumed.
5.6 OPERATING THE AIR
COMPRESSOR
The air compressor and the supply of high pressure air
can be turned off. Whenever the pressure in the air tank
drops below 150 psi or the set pressure, the engine will
run at high speed until the pressure in the tank reaches
175 psi or set pressure. the pressure gauge on the panel
displays the current tank pressure.
®
NOTE
at full speed.
NOTE
WARNING
090010-OP_r0
SECTION 5: OPERATION
Figure 5-4: Resettable Circuit Breakers
NOTE
The Air N Arc 300 Power System unit
features a high pressure, 175 psi air
system. Check the maximum air
pressure rating on the air tools being
used. The operator is responsible for
regulating the air pressure when
necessary (See Section 6.5.15, Adjusting
the Pressure Setting).