Instrument Panel - Compressor On Function - Vanair Air N Arc All-in-One Power Systems 300 Operations Manual & Parts List

Table of Contents

Advertisement

®
AIR N ARC
300 SERIES ALL-IN-ONE POWER SYSTEM
B.3.2 INSTRUMENT PANEL - COMPRESSOR ON FUNCTION
A
B
FUNCTION/ACTION
Compressor Switch
1
I
ON
I
The starting condition for operating the compressor begins after the engine state is in the pre-existing
RUN condition, as explained in Section B.2.4, Key to Run Function. As soon as the compressor switch
is toggled to the ON position, the engine will accelerate from low idle state to high speed, and remain as
long as the compressor switch is in the ON position and air is being used. If air pressure builds to full
pressure with no air usage for 2-1/2 minutes, the compressor clutch will disengage, and the engine will
return to idle speed.
NOTE: No condition lights will be illuminated.
®
C
SUSTAINED OR RESPONSE CONDITION
A
Hour meter constantly displays total hours; fuel level meter con-
tinues to display.
B
The ignition position is ON, with the engine operating in low
idle.
C
(NOTE: Initial air pressure gauge reading depends upon com-
pressor status when previously shut off). Air pressure accumu-
lates in air tank to desired working pressure.
Compressed air will be available at the machine outlet and both
II
D
outlets on the panel box (E).
090010-OP_r0
APPENDIX B: INSTRUMENT PANEL FUNCTIONS
D
1
E
PAGE - 171