®
AIR N ARC
300 SERIES ALL-IN-ONE POWER SYSTEM
TABLE 3E: VARIOUS FUNCTION ACCEPTABLE TESTING OUTPUT RANGES
Engine No-Load Hi RPM
Engine Idle RPM
Air Cut-in pressure
Air Cut-out pressure
AC generator Hz (no load)
AC generator 240 plug
AC generator 120 plug
AC generator 120 plug
Welder Max Voltage
Welder Min Voltage
Welder Max Amperage
Welder Max CV Voltage
Welder Min CV Voltage
Welder 12V charge voltage
Welder 12V boost voltage
Welder 24V boost voltage
TABLE 3F: GENUINE VANGUARD™ OIL CHARACTERISTICS
Viscosity
Flashpoint
Pour point
Contains
Contains
FUNCTION
178 SUS at 100°F (38°C)
495°F (257°C)
-49°F (-45°C)
Rust and Oxidation Inhibitors
Detergents
090010-OP_r0
®
ACCEPTABLE RANGE
1660+/-10
SECTION 3: SPECIFICATIONS
3660+/-10
//
670+/-20
100+/-5
125+/-10
61+/-1
243+/-3
122+/-2
122+/-2
70+/-10
20+/-5
300+/-5
40+/-2
14+/-2
14+/-1
16+/-1
29+/-1
PAGE - 35