AIR N ARC
300 SERIES ALL-IN-ONE POWER SYSTEM
• Ensure that the lines do not make contact
with sharp edges, moving parts or
exhaust heat (consult Appendix A,
Section A.6 Hose Installation Guide for
assistance in running hose lines).
• Units must have a 70 micron fuel filter in
line before the pump.
3. Install the remote control panel (Optional) at
the desired location on the service body and
route the control trunk line to the location
where the unit will mount. Ensure that all
sharp edges that the trunk-line contacts are
shielded or grommeted, and that there are
no excessively sharp bends in the trunk-line.
Ensure the trunk line does not come in
contact with exhaust parts.
4.4 MACHINE PACKAGE MOUNTING
When determining package position on vehicle, be aware
of the minimum space requirements needed for cooling
and circulation requirements, and also package access
for performing maintenance (see Figure 4-1, and
Diagrams 4.5 and 4.6).
1. Refer to Figure 4-4. Remove the truss screws
[B], nylon flat washers [C] in order to remove
access panel covers ([A] and [K]) found on
both side ends of the unit.
A
KEY
A
MOUNTING PATTERN WITH SPACER
B
MOUNTING PATTERN WITHOUT SPACER
10.5"
0.5Ø
5.0"
DESCRIPTION
Figure 4-3: Mounting Pattern (with and without Spacer)
090010-OP_r0
®
C
KEY
A
FUEL PUMP
B
FUEL FILTER
C
FUEL TANK
D
24" CLEARANCE TO BOTTOM
OF FUEL TANK
Figure 4-2: Fuel Pump Clearance
Mounting brackets are available to space
panel off from truck body (Figure 4-3).
B
10.5"
0.5Ø
PART NUMBER
(SPACER) A16738P
SECTION 4: INSTALLATION
B
A
D
DESCRIPTION
NOTE
Contact Vanair.
7.5"
_
PAGE - 39