APPENDIX B: INSTRUMENT PANEL FUNCTIONS
B.4.5 INSTRUMENT PANEL - WELDER CC FUNCTION
A
FUNCTION/ACTION
1
DC Welder/Charger
switch is in Welder
I
position
2
Switch for Constant
Current/Constant Volt-
age is in the CC posi-
tion
I
When DC Welder/Charger selector switch is in Welder position, all DC Charger mode controls will be
ignored, and the LEDs will be out.
II
The "On" function for a running system refers to the reverted condition of the ignition switch after the
engine has completed starting, as per Section B.2.4, Key to Run Function.
III
Each time an adjustment is made the display will show the setting briefly for approximately three (3)
seconds, and then return to the usage display.
NOTE: All other LEDs will be off.
PAGE - 176
AIR N ARC
2
1
C
SUSTAINED OR RESPONSE CONDITION
A
Hour meter constantly displays total hours; fuel level meter con-
tinues to display.
The ignition position is ON, with the engine operating in low
II
B
idle.
C
Amp LED is on; display briefly shows amperage setting
requested from potentiometer (D
age currently being used at the attached welder leads.
090010-OP_r0
®
300 SERIES ALL-IN-ONE POWER SYSTEM
III
), then will show the amper-
®