Display Messages - Pilz PNOZ m B0 Operating Manua

Configurable control system
Hide thumbs Also See for PNOZ m B0:
Table of Contents

Advertisement

Operation
Legend:
7.2

Display messages

The LC display has four lines. It displays information and navigates the menu:
Display
RUN
State of inputs/outputs and
supply voltage
ERROR
Status and error messages
DISPLAY MESSAGE
Display messages
PROJECT INFO
Project information
SHOW DEVICE INFO?
Show device information
DEVICE INFO
Device information for the
base unit and expansion
modules
SHOW ERROR STACK
Show error stack
Operating Manual PNOZ m B0
1002660-EN-02
LED on
LED flashes
LED off
Example
X3
X1
X2
T T
X4
M
Feedback
loop
E-STOP
pressed
PNOZ m B0
project
CRC: 0x8108
20.04.2012
Show device
info?
Pos:
0
PNOZ m B0
Version:
0000
Firmw.:
0100
Pos:
0
PNOZ m B0
H:
0
Show
error stack?
Description
The lines are assigned
terminals X1 ... X4
State:
Input active
Input inactive
Semiconductor output active
Semiconductor output inactive
Test pulse output
T
Display in the event of a message (bottom right):
Message is present
M
Error message is present
E
Line 1 ... 4: Status and error
messages as short text.
Line 1 ... 4: Customised
messages that are created in
the PNOZmulti Configurator.
Line 1: Project name
Line 2: Project name
Line 3: Check sum (CRC)
Line 4: Creation date
Show device information for
the base unit and expansion
modules
Line 1: Module position (Pos)
Line 2: Product type
Line 3: Device version
(Version)
Line 4: Firmware version
(Firmw.)
Shows the error stack entries
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

772 100

Table of Contents