4 SETUP AND PROCEDURES BEFORE STARTING THE OPERATION
No.
Name
LED status
1
RUN
Green on
2
MNG
Green on
3
T.PASS
Green on
Green flash Test is determined to have completed normally when this LED flashes 20 times or more
4
D.LINK
Green on
5
SD
Green on
6
RD
Green on
7
ERR.
Red on
Flashing
8
L ERR.
Red on
9
EXT. PW
Green on
*1: The ERR. LED flashes on the following modules whose first five digits of the serial number is "02112" or later.
• QJ71LP21
• QJ71LP21-25
• QJ71BR11
4 - 3
1) LED displays
Module operating normally
Off
Watchdog timer error occurred (hardware error)
Operating as a control station or sub-control station
Off
Normal station (not operating as a control station or sub-control station)
Executing baton pass (being joined in a network)
(approximately 10 s) during the test.
Off
Baton pass not yet executed (the host is disconnected from the network)
Data link being executed (cyclic transmission is being executed)
Off
Data link not yet executed (parameter receiving not completed, host CPU error, data link stop
instructed, etc.)
Data being sent
Off
Data not yet sent
Data being received
Off
Data not yet received
• An error occurred, for instance a station number setting error (other than 1 to 64), mode setting
error (set to use prohibited), operation condition setting error (parameters), or an installed CPU
type error (settings outside the range used, CPU type).
• A station with the same number already exists in the network.
• The host is designated as the control station even though a control station already exists in the network.
• Invalid parameter settings (contradicting settings).
• The parameters received from the sub-control station and the parameters retained by the host
(received from the control station) are different.
• A moderate or fatal error occurred in the CPU module.
• An error was detected while testing the network module.
• The mode setting switch or the station number setting switch was changed during operation. *1
Off
Normal status
A communication error occurred (one of the following communication errors has occurred):
CRC
: Error generated by an abnormal cable, noise, etc.
OVER
: This error occurs when the next data is received before the last receive data is loaded
into the module, and the data is overwritten. It is caused by a hardware error in the
receive area of the network module.
AB.IF
: This error occurs when more than the specified number of bits are set to "1" among the
receive data in the frame, or when the receive data is shorter than the specified data length.
TIME
: This error occurs when a baton pass was not handed to the host within the monitoring time.
DATA
: This error is caused when abnormal code data is received.
UNDER : This error occurs when the internal processing of the send data was not executed at a
fixed interval.
LOOP
: This error occurs when the forward or reverse loop line is faulty and the power to the
adjacent station, which sends data to the host station, is turned OFF or the cable
connector is faulty.
<Corrective action>
Check the cables and connectors (detached or loosened connectors, wrong IN/OUT
connections, broken or damaged cables, improper cable routing, etc.)
For more details, see the "Network Diagnostics" (Section 8.1).
Off
No communication error
External power being supplied (Host station power status (SB0042) is ON.)
Off
External power not supplied (Host station power status (SB0042) is OFF.)
Description
MELSEC-Q
4 - 3