7 APPLICATION FUNCTIONS
n3
Target station CPU type
(D1) First device storing the read clock data
Completion device (host)
Designate the host device to set scan 1 at ON when execution has been
completed.
(D2)
(D2)........ Off : Not completed
(D2)+1..... Off : Normal
If the execution is not normally completed, the corresponding error code will
be saved at SW0031 to SW003F. (For the error code, refer to Section 8.3.)
1: The CPU type can be specified when the host station is a network module of function version D or later. (The specification is not available for other
versions. The target station CPU will be accessed.)
2: If system switching occurs at the target station when the RTMRD instruction is executed to the redundant system with the control or standby system CPU
designated, the instruction may not be normally completed (error code: 4244
If the above-mentioned error occurs and the RTMRD instruction is not normally completed, retry to execute the instruction.
3: The following details of the read clock data are stored with the BCD code.
Device
Item
Year (lower two digits)/month the
(D1)
data was read
(D1)+1
Date/hour the data was read
(D1)+2
Minute/second the data was read
Year (higher two digits)/day the
(D1)+3
data was read
4: Bit device
5: Word device
6: Bit designation of word device : Word device. bit No.
7 - 93
Description of setting
3
On : Complete
On : Abnormal
b15
Year (lower two digits) (00
b15
Date (01
b15
Minutes (00
b15
Year (higher two digits) (19
: X, Y, M, L, F, V, and B
: T, C, D, W, ST, R, and ZR (The Q00JCPU and QS001CPU cannot use R and ZR.)
POINT
The readable range for the year (4 digits) is from 1980 to 2079.
Designate the CPU type of the target station.
Set value
Target station CPU/control CPU/host system CPU (The
0000
1
H
designation is the same as "03FF
03D0
1 Control system CPU
H
03D1
1 Standby system CPU
H
03D2
1 System A CPU
H
03D3
1 System B CPU
H
Multiple CPU No. 1 or target station CPU (in single CPU
03E0
H
system)
03E1
Multiple CPU No. 2
H
03E2
Multiple CPU No. 3
H
03E3
Multiple CPU No. 4
H
03FF
Target station CPU/control CPU/host system CPU
H
Word device
5
4
Word device
Bit device
4
Bit designation of word device
, 4248
).
H
H
Description
to
b8
b7
to
Month (01
to 99
)
H
H
to
b8
b7
to
to 31
)
Hour (00
H
H
to
b8
b7
to
to 59
)
Seconds (00
H
H
to
b8
b7
to
Day (00
/20
)
H
H
00
Setting range
Description
2
2
5
6
b0
to 12
)
H
H
b0
to 23
)
H
H
b0
to 59
)
H
H
b0
to 06
)
H
H
(Sunday) to 06
(Saturday)
H
H
MELSEC-Q
.")
H
7 - 93