7 APPLICATION FUNCTIONS
n3
Target station CPU type
n4
Mode
Complete device (host)
Designate the host device to set scan 1 at ON when execution has been
completed.
(D)
(D)
Off : Not completed
(D)+1 Off : Normal
If the execution is not normally completed, the corresponding error code will
be saved at SW0031 to SW003F. (For the error code, refer to Section 8.3.)
2: The CPU type can be specified when the host station is a network module of function version D or later. (The specification is not available when they are
other than the above. Access is made to the target station CPU.)
3: If system switching occurs at the target station when the RSTOP instruction is executed to the redundant system with the control or standby system CPU
designated, the instruction may not be normally completed (error code: 4244
If the above-mentioned error occurs and the RSTOP instruction is not normally completed, retry to execute the instruction.
4: The CPU type can be specified when the QCPUs of the host station and target station are the following versions. (The specification is not available when
they are other than the following. Access is made to the target station CPU.)
• QCPU: First 5 digits of the serial No. are "06092" or later
5: Settings each of the following modes.
b15
to
0
1) Operation mode
1
H
6: Bit device
7: Word device
8: Bit designation of word device : Word device. bit No.
7 - 87
Description of setting
On : Complete
On : Error
b4 b3 to b0
1)
(fixed)
: X, Y, M, L, F, V, and B
: T, C, D, W, ST, R, and ZR (The Q00JCPU cannot use R and ZR.)
POINT
(1)
Remote STOP is available when the RUN/STOP switch of the target station
CPU is set to "RUN".
(2)
Remote STOP is not possible when the system protection function has been
activated for the targeted station's CPU module.
(3)
The remote STOP information will be deleted if the target station's CPU
module for which remote STOP is being performed is reset.
Designate the CPU type of the target station.
Set value
Target station CPU/control station CPU/host system CPU
0000
2
H
(The designation is the same as "03FF
03D0
2 Control system CPU
H
03D1
2 Standby system CPU
H
03D2
2 System A CPU
H
03D3
2 System B CPU
H
Multiple CPU No. 1 or target station CPU (in single CPU
03E0
4
H
system)
03E1
4 Multiple CPU No. 2
H
03E2
4 Multiple CPU No. 3
H
03E3
4 Multiple CPU No. 4
H
03FF
Target station CPU/control CPU/host system CPU
H
Word device
7
Word device
7
5
Bit device
6
Bit designation of word device
, 4248
).
H
H
MELSEC-Q
Setting range
Description
.")
H
3
3
8
7 - 87