7 APPLICATION FUNCTIONS
(D1) First device storing the write clock data
Completion device (host)
Designate the host device to set scan 1 at ON when execution has been
completed.
(D2)
(D2)........ Off : Not completed
(D2)+1.... Off : Normal
If the execution is not normally completed, the corresponding error code will
be saved at SW0031 to SW003F. (For the error code, refer to Section 8.3.)
2: The CPU type can be specified when the host station is a network module of function version D or later. (The specification is not available when the are
other than the above. Access is made to the target station CPU)
3: If system switching occurs at the target system when the RTMWR instruction is executed to the redundant system with the control or standby system CPU
designated, the instruction may not be normally completed (error code: 4244
If the above-mentioned error occurs and the RTMWR instruction is not normally completed, retry to execute the instruction.
4: The CPU type can be specified when the QCPUs of the host station and target station are the following versions. (The specification is not available when
they are other than the following. Access is made to the target station CPU.)
• QCPU: First 5 digits of the serial No. are "06092" or later
5: The following details of the written clock data are stored with The BCD code.
Device
Item
(D1)
Amendment pattern
Year (lower two digits)/month the
(D1)+1
data write
(D1)+2
Date/hour the data write
(D1)+3
Minute/second the data write
Year (higher two digits)/day the
(D1)+4
data write
6: Bit device
7: Word device
8: Bit designation of word device
7 - 95
Description of setting
5
On : Complete
On : Abnormal
Specifies the item into which the (D1)+1 to (D1)+4 clock data is to be written.
0: Not amended
1: Amended
b15
Year (lower two digits) (00
b15
Date (01
b15
Minutes (00
b15
Year (higher two digits) (19
: X, Y, M, L, F, V, and B
: T, C, D, W, ST, R, and ZR (The Q00JCPU and QS001CPU cannot use R and ZR.)
: Word device. bit No.
POINT
(1) Clock data cannot be written when the system protection function has been
activated for the targeted station's CPU module.
(2) The writable range for the year (4 digits) is from 1980 to 2079.
Word device
Bit device
6
Bit designation of word device
, 4248
).
H
H
Description
b15
b8
b7 b6 b5 b4 b3 b2 b1 b0
to
0
0
to
to
b8
b7
to
Month (01
to 99
)
H
H
to
b8
b7
to
to 31
)
Hour (00
H
H
to
b8
b7
to
to 59
)
Seconds (00
H
H
to
b8
b7
to
Day (00
/20
)
H
H
00
Setting range
7
8
Year (lower two digits)
Month
Date
Hour
Minutes
Seconds
Day
Year (higher two digits)
b0
to 12
)
H
H
b0
to 23
)
H
H
b0
to 59
)
H
H
b0
to 06
)
H
H
(Sunday) to 06
(Saturday)
H
H