Csv Variables; Table 12:3 - Control File Variables - Xylem SonTek FlowTracker2 User Manual

Table of Contents

Advertisement

12.2.2

CSV Variables

The Variables that are exported in each of the Comma Separated Values files are
defined in the following tables with the variable name, description and applicability to
either the Discharge or General Modes.
The Control file consists of all the system information for both the handheld and probe
and the quality control parameter settings based on either default or user configuration.
The variables exported in the control file are given in
Table 12-3 - Control File Variables
Variable
Desktop_Software_Build_Version
Number_Of_Stations
Start_Time
End_Time
Local_Time_UTC_Offset_Hours
Handheld_Serial_Number
Handheld_CPU_Serial_Number
Handheld_Boards_Info
Handheld_Software_Version
Handheld_Operating_System
Wading Rod
ADV_System_Frequency
ADV_Serial_Number
ADV_Firmware_Version
ADV_Number_Of_Beams
ADV_Noise_Level
ADV_Peak_Position
ADV_Peak_Level
Configuration_Data_Collection_Mode
Configuration_Averaging_Time
Configuration_Sampling_Rate
Configuration_Salinity
Configuration_Temperature
Configuration_Sound_Speed
Configuration_Mounting_Correction
Configuration_Quality_Control_SNR_Thr
eshold
Configuration_Quality_Control_Std_Error
_Threshold
Configuration_Quality_Control_Spike_Th
reshold
Configuration_Quality_Control_Velocity_
Angle_For_Warning
Configuration_Quality_Control_Tilt_Angl
e_For_Warning
FlowTracker2 User's Manual (January 2019)
Table
Mode
D, G
Version of desktop software
D, G
Station number
D, G
Start time of measurement
D, G
End time of measurement
D, G
Local time offset for UTC in hours
D, G
Handheld serial number
D, G
Handheld CPU serial number
D, G
Handheld boards info
D, G
Handheld software version
D, G
Handheld operating system
D
Type of wading rod
D, G
ADV system frequency
D, G
ADV serial number
D, G
ADV firmware version
D, G
ADV number of beams
D, G
ADV noise level
D, G
ADV peak position
D, G
ADV peak level
D, G
Data collection mode
D, G
Averaging time
D, G
Sampling rate
D, G
Salinity measured using external sensor
D, G
Temperature internal or external measured
D, G
Sound Speed calculated or external measured
D, G
Mounting Correction in percentage
D, G
SNR Threshold for quality control process
D, G
Std Error Threshold for quality control process
D, G
Spike Threshold for quality control process
D, G
Velocity Angle for quality control process
D, G
Tilt Angle for quality control process
208
SonTek – a Xylem brand
12:3.
Description

Advertisement

Table of Contents
loading