Shared System 25 Voice/Starlan Network Data; Connections; Single-Line Voice Terminals - AT&T Network Adapter 25 Installation And Maintenance Manual

Adtran network adapter product manual
Hide thumbs Also See for Network Adapter 25:
Table of Contents

Advertisement

Shared System 25 Voice/STARLAN NETWORK

Connections

STARLAN NETWORK workstations can share the 4-pair System 25 wiring to
the SIP with an analog or 7300H Series voice terminal. The STARLAN
NETWORK data is transmitted over pairs two and three. At the SIP, the data
pairs and voice pair(s) are
(WP90851 ,L1 ). The data pairs are connected to the STAR LAN NETWORK
NEU. For analog single-line voice terminals, the voice pair is connected by
an octopus cable to a ZTN78 CP. For 7300H Series voice terminals, the
voice pairs are connected to a ZTN79 CP. A KS-23475, L1 Adapter and a
KS-2291 1 Power Unit are also required at the workstation to provide power
to the 7300H Series voice terminal.

Single-Line Voice Terminals

See Figure 2-50.
1.
Unpack each terminal and examine it for damage.
2. At the workstation, connect one end of the terminal line cord to the
terminal and the other end to the PHONE jack on the NAU.
3. Using a D8W-87 modular cord, connect the OUT jack on the NAU to
the modular wall jack.
4 .
Locate the workstation appearance at the SIP, and disconnect the
octopus cable. Install a WP90581, L1 Y
octopus cable plug to the VOICE jack.
5. Using a D8W-87 modular cord, connect
Adapter to the STARLAN NETWORK NEU
separated by the standard Y-adapter
Adapter, and connect the
the DATA jack on the Y
IN jack.