APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
1 0 8 3 : inappropriate request
TT generator not installed generator was installed.
1084:
inappropriate request
system already has two
CAPS
1085: incorrect entry
must be 0-3 if parity, else
0-1
1 0 8 6 : inappropriate request
DID trunk can't have
Trunk ID
1 0 8 8 : entry out of range
data must be 10-255
1089:
entry out of range
port can't exceed 5 digits
1090:
at installed max
-1 data button
1091:
incorrect entry
data must be 0-7
1092:
incorrect entry
Trunk ID must be 9
characters or less
F-8
POSSIBLE SOLUTION
Recheck translations to see if TT
Trying to administer a third CAP
when you are only allowed two.
Data parity setting must be between
0-3. Delay break for STARLAN is
0 - 1 .
Cannot assign a DID trunk port an
(ID) name. Go to MENU 1 (Port)
ACTION = 90
DATA = "name-not-allowed " for
DID trunk.
SMDR billing must be between
10-255 seconds
MENU = 4 (System)
ACTION = 53
DATA = 10-255
Port number cannot exceed 5 digits.
Can only associate 1 data button
with a PDC.
Switched Loop Console call type
priority must be between 0-7. See:
MENU = 4 (System)
ACTION = 92
for more information.
You are exceeding the amount of
characters that a trunk name (ID)
can be.