2-3. Ribbon Drive Assembly

1. Replace the ribbon drive assembly. (Refer to Section 1-6-2.)
2. Sets the ratio of takeup tension. (Refer to Section 2-3-1.)

2-3-1. Setting of Takeup Tension Ratio

1. Starts the service mode. (Refer to Section 5-2.)
2. Click the [Setting] button.
A Setting screen then appears.
3. Click the [Open] button of the Setting.
A Setting screen then appears.
4. Enter the value (described in item "C" at the bottom) written down during replacement of a ribbon
drive assembly (refer to Section 1-6-2) without using a decimal point in Take Up Ratio box.
Example: 1.54 → 154
5. Click the [Apply] button, then click the [Close] button.
6. Click the [Print|step] in a Diag Menu and print a test pattern (16STEP).
7. Check that the test pattern is printed normally.
2-10 (E)