4. Replacement and Adjustment
Waste Toner Lower Transport
1. PSU1/PSU2 along with the bracket (
are behind the PSU1/PSU2")
2. Relay duct with swinging plate (
3. Waste toner lower transport [A] ( x 2)
• Check the position of the hooks in the photo below before removing.
• When installing, first install the waste toner lower transport, then install the relay duct with
swinging plate. (
1024
page 944 "When removing the motors and sensors that
page 1016 "Waste Toner Bottle Unit")