Ricoh MP C6502SP Field Service Manual page 1524

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
Other
Adjusts Corner Stapler Jogger width (Main Scan position) when jogging specified
papers.
014
• Default setting of the follow units was changed to Pre-stack off (SP6116-001 to –014: -1)
• D13717: E253C900048-
• D13721: E253C920001-
• D13727: E253C930029-
• D13729: E253C950005-
• D13817: E263C900001-
• D13727: E263C920019-
• D13827: E263C930001-
• D13829: E263C950001-
Shift Tray Stalls Causing Paper Jam
Symptom
The shift tray [A] unexpectedly stalls at its highest or lowest positions and causes paper jams.
Cause
The shift tray paper feeler [A] is out of position.
1522
• Adjustment Value "-": Movement in the direction that Jogger width becomes
narrower than the standard value,
• Adjustment Value "+": Movement in the direction that Jogger width becomes
wider than the standard value.
*ENG
[-1.5 to 1.5 / 0.0 / 0.5mm/step]