After Installing The New Hdd Unit; Disposal Of Hdd Unit; Reinstallation - Ricoh MP C6502SP Field Service Manual

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

After Installing the New HDD Unit

1. Do SP5-832-001 to format the hard disk.
2. Do SP5-853-001 to copy the preset stamp data from the firmware to the hard disk.
3. Do SP5-846-052 to copy back the address book to the hard disk from the SD card to which you
havealready copied the address book data if possible.
4. Turn the main power switch off/on.
• Make sure the cables are correctly connected on the controller board.
Red cable: Upper socket
Black cable: Lower socket
• If the connections are reversed, the machine will issue an error at startup. If it occurs just
reconnect the HDD correctly and start again. The HDD will not be damaged by such an
incorrect startup.

Disposal of HDD Unit

• If the customer has any concerns about the security of any information on the HDD, the HDD
mustremain with the customer for disposal or safe keeping.
• The HDD may contain proprietary or classified (Confidential, Secret) information. Specifically,
theHDD contains document server documents and data stored in temporary files created
automaticallyduring copy job sorting and jam recovery. Such data is stored on the HDD in a
special format so itcannot normally be read but can be recovered with illegal methods.

Reinstallation

• Explain to the customer that the following information stored on the HDD is lost when the HDD
isreplaced: document server documents, fixed stamps, document server address book
Main Boards / HDD Unit