CLMD12 User's Manual
Figure 9 – CLMD12 Advanced Tab

3.5.5.1 Device Instance

This parameter allows you to configure the NMEA 2000 device instance used by the device.
This value is also used as the data instance in the 127501 Binary Status Report messages
transmitted by the device and can be seen on the General Tab as well as the Inputs Tab
labeled as "Instance".

3.5.5.2 Transmit PGN 127501

This parameter allows you to configure whether the device transmits the 127501 Binary Status
Report NMEA 2000 message. If this field is set, the device will transmit the 127501 Binary
Status Report message along with proprietary messages. If this field is cleared, the device will
not transmit the 127501 message and will transmit only proprietary messages.