GC2e Wireless Security System | Installation and Programming Guide
Installer Testing
When installation and programming is complete, use the
option in the Installer Toolbox to test for proper system
operations.
Access the Installer Toolbox
To access the Installer Toolbox:
At the Home screen, tap the system logo in the lower-
1.
right corner .
At the Enter a Code screen, enter the installer code (the
2.
default installer code is 1561) .
The Installer Toolbox(1 of 3) screen appears .
Disable/Enable Sounder
When testing the Control Panel, both the internal and external
sounder (if installed) will be activated. To limit noise during
the testing process, the Control Panel offers an option to
disable the sounder .
Disable the Sounder
To disable the sounder:
At the Installer Toolbox (1 of 2) screen, tap Disable
1.
Sounder .
At the Disable Sounder? screen, tap OK. NOTE: The
2.
internal sounder emits a siren for two (2) seconds . If
an external sounder is connected, four (4) chirps are
emitted.
At the Sounder Disabled screen, tap OK .
3.
NOTE: The sounder will be automatically re-enabled in 30
minutes or you can manually enable it. See "Enable the
Sounder", below.
While disabled, the Sounder Disabled icon appears in the
4.
status bar .
Figure 57
Sounder Disabled Icon
Enable the Sounder
If the sounder is disabled, you can manually re-enable it as
follows:
At the Installer Toolbox screen, tap Enable Sounder .
1.
At the Sounder Enabled screen, tap OK .
2.
Sensor Type (Zone) Report Test
To verify that the Central Station correctly receives reports
from each zone (sensor type):
Notify the Central Station . Because the system sends
1.
test signals, notify the Central Station that you will be
testing the system.
Fire Test. Trigger a 24-Hour fire sensor (if installed)
2.
or tap the Control Panel's Emergency
and then tap the Fire button (if enabled). Wait for
approximately 45 seconds for the report to complete,
then disarm the console .
Panic Test. Trigger a 24-Hour Panic sensor (if
3.
installed) or tap the Control Panel's Emergency
button and then tap the Panic button (if enabled).
Wait about 45 seconds for the report to complete,
then disarm the console .
Emergency Test. Trigger a 24-Hour emergency sensor
4.
(if installed) or tap the Emergency
enabled), wait ab out 45 seconds for the report to
complete, then disarm the console .
Burglary Test . Arm the system, then trigger a
5.
burglary sensor, wait for the system to go into alarm
mode, then wait about 45 seconds for the report to
complete, and then disarm the console .
Verify Tests with Central Station . Check with the
6.
Central Station that each zone (sensor type) was
reported, then inform the Central Station that the
testing is complete.
Walk Test
Radio quality can vary when there is background noise on
the operating frequency. Examples of background noise
sources include telephones, microwaves, high-frequency
digital products, and other radio communications.
To determine the best location to mount each sensor, it is
recommended that you place each sensor in the desired
mounting location and then perform a Walk Test. This
helps you to identify whether the desired location has
good/weak signal strength. When you find a location with
good signal strength, you can then mount the sensor .
To place the panel into Walk Test mode:
At the Installer Toolbox (1 of 2) screen, tap Walk Test .
1.
NOTE: When placing the Control Panel into Walk Test
mode, you have 25 minutes to complete the test before
the screen times out. The system also sends a "Start Test"
report to the Central Station and beeps once every 30
seconds. During the last five (5) minutes of the test, the
system beeps two (2) times every 30 seconds and the
icon flashes in the status bar.
Copyright © 2018 Nortek Security & Control
button
button (if
61
Need help?
Do you have a question about the 2GIG e Series and is the answer not in the manual?