Sensor Type (Zone) - Nortek Security & Control 2GIG e Series Installation And Programming Manual

Wireless security system
Hide thumbs Also See for 2GIG e Series:
Table of Contents

Advertisement

GC2e Wireless Security System | Installation and Programming Guide

Sensor Type (Zone)

(32) Remote Device*
† Indicates Sensor types that are not allowed for hardwired loops .
* Sensor Type Reporting is only supported on Alarm .com .
Description
This zone type is selected by the installer when pairing the panel with peripheral devices that can utilize
localized troubles (such as RF jam, low battery, tamper, or AC loss detected by the peripheral device).
This sensor is continuously active and will cause a trouble at the panel for all problem conditions. When
the panel is in an armed state, this sensor type will cause an alarm for TAMPER and RF JAM . All trouble
conditions will be sent to the monitoring station if reporting is enabled with the exception of AC LOSS.
This will only be displayed at the panel .
Sensor Types (Zones)
Copyright © 2018 Nortek Security & Control
34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2GIG e Series and is the answer not in the manual?

This manual is also suitable for:

Gc2e

Table of Contents