GC2e Wireless Security System | Installation and Programming Guide
Control Panel Programming
Programming Questions
Q1: RF Sensor Programming
To learn about RF sensor programming, see
Sensor Programming" on page
Q2: Wired Sensor Programming
To learn about wired sensor programming, see
Sensor Programming" on page
Q3: RF Key Fob Programming
To learn about RF key fob programming, see
Keyfob Programming" on page
Q4: RF Keypad Programming
To learn about RF keypad programming, see
Keypad Programming" on page
Q5: Exit Delay, in Seconds (45-120)
DEFAULT: 60 seconds
The default minimum setting of 60 seconds is required
for ANSI/SIA CP-01 compliance. The delay time can be
increased without affecting compliance.
The exit delay timer can be set to a value between 45 to
120 seconds.
•
The default setting 60 sets the exit delay to 60 seconds.
•
To change the exit delay timer, enter a value between
45‐120 seconds .
Q6: Entry Delay 1, in Seconds (30-240)
DEFAULT: 30 seconds
The default minimum setting of 30 seconds is required for
ANSI/SIA CP‐01 compliance.
NOTE: For compliance with ANSI/SIA CP‐01, the total
number of minutes for the combination of Q6: Entry Delay
1 and Q35: Abort Window Dialer Delay cannot exceed one
(1) minute.
The timer for Entry Delay 1 can be set to a value between
30 to 240 seconds.
•
The default setting 30 sets the timer to 30 seconds.
•
To change the setting, enter a value between 30‐240
seconds .
Q7: Entry Delay 2, in Seconds (30-240)
DEFAULT: 45 seconds
The default minimum setting of 45 seconds is required for
ANSI/SIA CP‐01 compliance.
NOTE: For compliance with ANSI/SIA CP‐01, the total
number of minutes for the combination of Q7: and Q35:
Abort Window Dialer Delay cannot exceed one (1) minute .
The ti mer for Entry Delay 1 can be set to a value between
30-240 seconds:
•
The default setting of 45 sets the timer to 45 seconds.
•
To change the timer setting, enter a value between
30‐240 seconds .
"Wireless (RF)
38 .
"Wired
41 .
"Wireless (RF)
44 .
"Wireless (RF)
46 .
Q13: 2-Way Voice (0-2)
DEFAULT: (1) Stay On Line
The Control Panel supports two (2)-way voice communications
between the subscriber and the Central Station operator over
the LTE (Cellular) Radio Module (if installed) after an alarm has
been reported .
•
The (1) Stay On Line allows two (2)-way audio over the cell
radio .
•
Selecting (2) Stay On Line, Including Fire and CO Alarms
allows 2-way audio over cell radio during fire and CO
alarms .
•
To turn off the two (2)-way audio feature OFF, select (0)
Disabled .
When the Control Panel connects with the operator, it will beep
once per second (every 6 seconds with a cell radio connection).
The beep alternates between two tones and indicates the
Control Panel is waiting for a session command. If the operator
fails to issue a command within one (1) minute (or three (3)
minutes if using the cell radio connection), the call is terminated.
Once the operator presses a command option, the beeps will
stop and a five (5)-minute audio session will start (or three (3)-
minute audio session if using the cell radio connection).
When two (2)-way voice communications have been established,
the Central Station operator can use the following telephone
keys to control the communications. Each time the operator
uses a command key, the session is extended for five additional
minutes (three minutes with a cell radio connection). During the
last minute of communications, the system beeps two (2) time s
every 15 seconds to indicate that time is running out.
•
Tap 1 to enable Talk mode one (1)-way communication from
the Central Station to the premises and allows the operator
to talk .
•
Tap 2 to enable VOX mode two (2)-way communications
from the Central Station to the premises.
•
Tap 3 to enable Listen mode one (1)-way communication
from the premises to the Central Station.
•
Tap 7 to extend the session five (5) minutes without
changing the mode of operation.
•
Tap 9 to end the audio session an terminate the call .
Q14: Silent Panic/Burglary Listen Only
DEFAULT: (1) Enabled
The Control Panel supports audio listen-in of the subscriber
premises from the Central Station after a silent panic (police
emergency), silent burglary, or duress alarm has been reported .
•
The default setting (1) Enabled allows the Central Station to
use listen-in over audio after a silent panic, silent burglary,
or duress alarm .
•
This option is permanently set and cannot be disabled.