GC2e Wireless Security System | Installation and Programming Guide
Q53: System Low Battery Reports to CS (0-1)
DEFAULT: (1) Enabled
Low battery reports can be sent to the Central Station if the
Control Panel's battery tests low.
•
The default (1) Enabled allows Control Panel low battery
reports .
•
To turn off Control Panel low battery reports, select (0)
Disabled .
Q54: RF Low Battery Reports to CS (0-1)
DEFAULT: (1) Enabled
Sensor low battery reports can be sent to the Central Station if a
sensor battery tests low and sends a low battery transmission to
the Control Panel .
•
The default setting is (1) Enabled and allows the system to
send low battery reports for sensors.
•
To turn this feature OFF, select (0) Disabled .
Q55: Opening Reports to CS (0-1)
DEFAULT: (0) Disabled
Opening reports can be sent to the Central Station each time the
system is disarmed . The user or key fob number is indicated in the
opening report .
•
The default setting (0) Disabled prevents opening reports .
•
To allow opening reports, select (1) Enabled .
Q56: Closing Reports to CS (0-1)
DEFAULT: (0) Disabled
Closing reports can be sent to the Central Station each time the
system is armed . The user or key fob number is indicated in the
closing report. If Quick Arming is enabled, User #0 is indicated for
the closing report .
•
The default setting (0) Disabled prevents closing reports .
•
To allow closing reports, select (1) Enabled .
Q57: Alarm Restore Reports to CS (0-1)
DEFAULT: (0) Disabled
Alarm restore reports can be sent to the Central Station after
an alarm when either the bell timeout has been reached or the
system is disarmed . If alarm restores are enabled and swinger
shutdown is set to two, a restore will be reported if the sensor is
closed (normal st ate) at bell cutoff or becomes closed after bell
cutoff. If swinger shutdown is set to one, a restore will only be
sent if the sensor is closed at the time of disarm. Restores are not
sent if a sensor is in swinger shutdown until the time of disarm
and the sensor is closed .
•
The default setting (0) Disabled prevents alarm restore
reports .
•
To allow alarm restore reports, select (1) Enabled .
Q58: Trouble Restore Reports to CS (0-1)
DEFAULT: (1) Enabled
Trouble restore reports can be sent to the Central Station when
any sensor trouble condition clears.
•
The default setting (1) Enabled allows the system to send
reports when trouble conditions are restored.
•
To turn this feature OFF, select (0) Disabled .
Q59: Bypass Restore Reports to CS (0-1)
DEFAULT: (0) Disabled
Bypass restore reports can be sent to the Central Station
when any sensor that was force bypassed or manually
bypassed gets restored .
•
The default setting (0) Disabled prevents bypass
restore reports .
•
To allow bypass restore reports, select enabled (1)
Enabled .
Q60: AC Restore Reports to CS (0-1)
DEFAULT: (1) Enabled
AC power restore reports can be sent to the Central Station
when the Control Panel regains AC power after an AC
power loss .
•
The default setting (1) Enabled allows AC power
restore reports .
•
To turn off AC power restore reports, select (0)
Disabled .
NOTE: The AC power will have to be restored to the Control
Panel for one minute before the AC power loss trouble alert
automatically clears. If programming question Q39 is
enabled, the actual AC power restore report will occur at
a random time of up to four hours after the AC power loss
trouble alert
has cleared .
NOTE: The Control Panel's AC power icon displays the
power status. A red "X" over the icon indicates no AC
power .
Q61: System Low Battery Restore
Reports to CS (0-1)
DEFAULT: (1) Enabled
When a low battery condition is restored on the Control
Panel, the system can send a restore report to the Central
Station.
•
The default setting (1) Enabled allows the system
to send reports when low battery conditions are
restored .
•
To turn this feature OFF, select (0) Disabled .
Q62: RF Low Battery Restore Reports to
CS (0-1)
DEFAULT: (1) Enabled
Sensor low battery restore reports can be sent to the
Central Station if a sensor battery had tested low and is
now OK .
•
The default setting (1) Enabled allows sensor low
battery restore reports.
•
To turn off sensor low battery restore reports, select
(0) Disabled .
Copyright © 2018 Nortek Security & Control