GC2e Wireless Security System | Installation and Programming Guide

Q35: Abort Window Dialer Delay (0-2)

DEFAULT: (1) 30 Seconds
The default minimum setting for ANSI/SIA CP-01 compliance is
30 seconds.
The delay time can be increased to 45 seconds without affecting
ANSI/SIA CP-01 compliance only if the combination of Q35 and
Q6 or Q7 does not exceed one (1) minute .
NOTE: The dialer delay can be disabled for each sensor
without affecting ANSI/SIA CP-01 compliance. See
Programming Questions" on page
The system delays calling the Central Station to allow the user
enough time to cancel a false alarm before it is reported.
The default setting is (1) 30 Seconds .
To change the setting, select (0) 15 Seconds or (2) 45
Seconds .

Q36: Burglary Bell Cutoff (0 to 4)

DEFAULT: (0) 4 Minutes
When a burglary alarm is triggered, the bell will sound until the
burglary bell cutoff time expires.
The default setting for the burglary bell cutoff is (0) 4
Minutes .
To change the cutoff time, select an option below.
Burglary Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited
NOTE: The 24-hour Auxiliary Alarm Zone (08) does not follow
the burglary bell cutoff time and will sound the Control Panel's
local alarm until a User Code is entered. The Auxiliary Alarm
Zone does not trigger the external siren (if used) .

Q37: Fire Bell Cutoff (0-4)

DEFAULT: (0) 4 Minutes
When a fire alarm is triggered, the bell sounds until the fire bell
cutoff time expires.
The default setting (0) 4 Minutes sets the burglary bell
cutoff to four (4) minutes.
To change the fire bell cutoff time, select an option below:
Fire Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited

Q38: Time to Detect AC Loss, in Minutes (0-30)

DEFAULT: (10) 10 Minutes
When AC power is lost, they system displays a power loss alert
"RF Sensor
39 .
after the specified time length. When power is restored, the alert is
automatically cleared after one (1) minute.
The default detection timer for displaying the alert message is
(10) 10 Minutes .
To change the detection timer, enter a value between 0 to 30
minutes .
NOTE: After the AC power alert
power loss report or AC power restore report can be sent to the
Central Station immediately, or at a random time, see Q39: Random
AC Loss Report Time .
NOTE: The Control Panel's AC Power Icon immediately displays the
power status .
See "AC Power ON/OFF" on page

Q39: Random AC Loss Report Time (0-1)

DEFAULT: (1) Enabled
This feature allows the system to report AC power loss and AC power
restore at a random time of up to 45 minutes after the event occurs.
This helps to reduce Central Station congestion due to a wide-spread
power outage affecting many Control Panels at once. The random AC
power status report timer is triggered based on the time set by Q38:
Random AC Loss Report Time .
The default setting (1) Enabled turns this feature ON .
To turn this feature OFF, select (0) Disabled .
NOTE: The installer code must be unique from the master user code
and all other user codes .

Q43: Installer Code (4 Digits)

DEFAULT: 1561
The installer code is a unique code that installation technicians use to
access the Installer Toolbox on the Control Panel .
The default installer code is 1561 .
To change the installer code, enter a new four (4)- digit code.
IMPORTANT: If you change the installer code, always write it down so
that you can access the system later .

Q44: Lock Installer Programming (0-2)

DEFAULT: (0) Disabled
The installer programming lockout feature is provided to prevent
takeovers . The Control Panel can be set to limit an installer's access to
programming questions after a period of 48 hours. The 48-Hour Lockout
timer starts when the installer exits System Configuration mode.
Three (3) options are available:
Unlimited full access to programming (no lockout) .
Limited access to programming after 48 hours.
No access to programming after 48 hours The default setting
(0) Disabled selects unlimited full access to programming (no
lockout) .
To deny access to programming after 48 hours, select (1) No Access to
Programming .
If you select (2) Limited Access to Programming the installer will be
able to view, but not change the following attributes after the system
has run for 48 hours, the Central Station phone number, Central
Station account number, lock installer programming, download ID,
and default lockout fields.
After the 48 hour lockout timer has locked out the system, the timer
can be reset through the cell radio or PC download by remotely
setting this question to (0) or (2). Setting the option to (0) or (2) will
restart the 48 hour lockout timer.
Copyright © 2018 Nortek Security & Control
Control Panel Programming
is displayed or clears, the AC
25 .
52

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2GIG e Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Gc2e

Table of Contents