Q93: Enter Broadband Network Failure Time (1-255); Q94: Select Broadband Network Failure Causes Trouble (0 To 1); Q95: Select Broadband Network Failure Reports (0 To 1); Q96: Select Send Report 3 Times On Panel Tamper (0 To 1) - Nortek Security & Control 2GIG e Series Installation And Programming Manual

Wireless security system
Hide thumbs Also See for 2GIG e Series:
Table of Contents

Advertisement

GC2e Wireless Security System | Installation and Programming Guide
Q: Select Port # (1 to 8)
DEFAULT: (1) Port 1
NOTE: Typically, you will skip this question unless additional
programming is required .
Select the port number for the backend server. After configuring
the required port, tap Next on the Control Panel .
(1) Port 1
(2) Port 2
(3) Port 3
(4) Port 4
(5) Port 5
(6) Port 6
(7) Port 7
(8) Port 8
Q: Select Used (0 to 1)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless additional
programming is required .
It is re commended that you always select the default setting
(0) Disabled . If you choose (1) Enabled, you will be prompted to
enter the port value .
Q: Enter Port Value (0 to 65535)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless additional
programming is required .
It is re commended that you always select the default setting (0)
Disabled . If you select (1) Enabled in Q: Select Used (0 to 1), use
the numeric keypad to enter the port value .
NOTE: The port value is the port number for Transmission
Control Protocol (TCP) communication. Port numbers can range
from 0 to 65535.
Q: Enter Port Forward IP Address
DEFAULT: 000.000.000.000
Typically, you will simply accept the default IP Address value
that appears .
Q93: Enter Broadband Network Failure
Time (1-255)
DEFAULT: 30 Minutes
NOTE: The Go!Bridge IP Communicator must be installed to use
this function.
This option sets the amount of time required for triggering a
trouble condition if the system detects that the broadband
network has lost its connection. After the connection has been
restored, the trouble condition clears.
The default failure detection setting is 30 minutes .
To choose a different failure detection time, enter the
number of minutes between 1‐255 .
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to
use this function.
This option specifies whether or not the Control Panel
will sound and display a trouble alert if the Go!Bridge IP
Communicator loses its broadband connection. The trouble
alert can be silenced by the user at the Control Panel
(broadband trouble is logged regardless of this setting). When
the broadband connection is re stored, the trouble indications
automatically clear.
The default setting (1) Enabled allows Go!Bridge network
failure trouble indications.
To turn off Go!Bridge trouble indications, select (0)
Disabled .
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to
use this function.
If the Go! Bridge IP Communicator loses its broadband
connection, the Control Panel can report the fault.
The default setting is (1) Enabled which turns broadband
network failure reporting ON.
To turn broadband network failure reporting OFF, select
(0) Disabled .
Q96: Select Send Report 3 Times on Panel
Tamper (0 to 1)
DEFAULT: (1) Enabled
NOTE: For compliance with UL 1610, this question must be set
to (1) disabled .
This option configures the system to transmit three (3) reports
to the Central Station when the system detects that the panel's
backplate is in a tamper condition.
(1) Enabled . The system transmits three (3) reports to the
Central Station.
(0) Disabled . The system only transmits a single report to
the Central Station.
Q97: Select Sound on Normal Closing
Acknowledgment (0 to 1)
DEFAULT: (1) Enabled
Configures the system to emit a sound when the system
acknowledges that an open sensor has closed (i .e ., returned to
its normal state) .
(1) Enabled . The system emits a sound on sensor closing .
(0) Disabled. No sound is emitted on sensor closing.
NOTE: For compliance with UL 1610, this question must be
set to (1) Enabled. In addition, Q91 must be set to (1) Radio