GC2e Wireless Security System | Installation and Programming Guide
Q45: Lock Default Programming (0-2)
DEFAULT: (0) Default All
The Control Panel may be able to be hard reset (or soft
reset from the Installer Toolbox) to its factory default values
depending on the value entered for this programming question.
The Control Panel is hard reset by pressing and holding the
and
buttons while applying power to the Control Panel.
The default lockout feature is provided to prevent takeovers .
Three options are available: allow default of all options, allow
default of some but not all options, not allow default of any
options.
•
The default setting of (0) Default All allows resetting the
Control Panel to all its factory defaults .
•
To allow resetting the Control Panel to all its factory
defaults except the Central Station phone number, Central
Station account number, lock installer programming,
download ID, and default lockout fields, select (1) Default
All Except CSID, Account/ Phone, Lockouts .
•
To deny hard and soft resetting of the Control Panel, select
(2) Default None .
If option 1 or 2 is selected, the option takes effect after the
system runs for 48 hours . This allows the installer to go back
and make changes if required .
Q46: Trouble Doesn't Sound at Night (0-1)
DEFAULT: (1) Enabled
NOTE: For UL 985: Household Fire Warning System Units
installations, this setting must be set to (0) Disabled
The Control Panel will sound trouble beeps caused by AC loss,
system low battery, sensor low battery or RF supervision, failure
to communicate, Control Panel tamper while disarmed, and cell
radio faults .
To prevent annoying the subscriber, the system can be set to
suppress trouble beeps from sounding from 10
trouble alerts are still displayed and immediately reported to
the Central Station, and can be acknowledged, but they won't
sound beeps until after 9
AM
If the trouble condition(s) self-clear or are acknowledged before
9
, no trouble beeps sound after 9
AM
recorded in the event log) .
•
The default setting (1) Enabled suppresses trouble beeps
from 10
to 9
PM
AM .
•
To allow trouble beeps at any time, select (0) Disabled .
Q47: Trouble Resound After Hold Off (0-7)
DEFAULT: (0) Disabled
Fire and CO sensors are required to re-sound trouble beeps
every four hours until the trouble is resolved, even if the trouble
is acknowledged at the Control Panel . The Control Panel can be
set to delay re-sounding these types of trouble beeps for 1-7
days .
NOTE: This feature is not allowed in UL 985 installations. The
setting must be (0) Disabled in this grade of installation.
•
The default setting (0) Disabled allows trouble beeps for
CO and fire sensors to re-sound every four (4) hours after
being acknowledged
•
To delay re-sounding trouble beeps for CO and Fire
sensors, select (1-7) days
to 9
. The
PM
AM
.
(the conditions are still
AM
Q49: Programming Mode Entry Reports to
CS (0-1)
DEFAULT: (0) Disabled
A report can be sent to the Central Station any time installer
programming mode is entered and exited .
•
The default setting (0) Disabled prevents reporting
programming mode entry and exit .
•
To report programming mode entry and exit, select (1)
Enabled .
NOTE: This report can only be sent through the telephone
dialer . It is not supported through the LTE (Cellular) Radio
Module .
Q50: Trouble Reports to CS (0-1)
DEFAULT: (1) Enabled
Trouble reports can be sent to the Central Station when any
sensor trouble condition occurs.
•
The default setting (1) Enabled allows reporting sensor
trouble conditions.
•
To not report sensor trouble conditions, select (0)
Disabled .
NOTE: This setting does not affect trouble reports caused
by Control Panel conditions, only trouble reports caused by
sensors .
Q51: Manual Bypass Reports to CS (0-1)
DEFAULT: (0) Disabled
Manual bypass reports can be sent to the Central Station
when any sensor has been manually bypassed by the user .
•
The default setting (0) Disabled prevents sending manual
bypass reports .
•
To allow sending manual bypass reports, select (1)
Enabled .
Q52: AC Loss Reports to CS (0-1)
DEFAULT: (1) Enabled
AC power loss reports can be sent to the Central Station if the
Control Panel loses AC power .
•
The default setting (1) Enabled allows AC power loss
reports .
•
To turn off AC power loss reports, select (0) Disabled .
NOTE: The AC power will have to be absent from the Control
Panel for the time set by programming question Q38 before
the AC power loss trouble alert
is 10 minutes). If programming question Q39 is enabled, the
actual AC power loss report will occur at a random time of
up to four hours after the AC power loss trouble alert
displayed .
NOTE: The Control Panel's AC power icon displays the power
status immediately. A red "X" over the icon indicates no AC
power .
Copyright © 2018 Nortek Security & Control
Control Panel Programming
is displayed (the default
is
53