GC2e Wireless Security System | Installation and Programming Guide
Q#
Programming Question/Sub-Question
Q21
Select Siren Supervision Time (0 to 3)
Q22
Enter CS Lack of Usage Notification Time, in Days (0-255)
Q23
Enter Radio Modem Network Failure Time (0-255)
Q24
Select Radio Network Failure Causes Trouble (0 to 1)
Q25
Select Radio Modem Network Failure Reports (0 to 1)
Q26
Select Auto Stay (0 to 1)
Q27
Select Exit Delay Restart (0 to 1)
Q28
Select Quick Exit (0 to 1)
Q29
Enter Periodic Test, in Days (0-255)
Q31
Enter Cancel Time, in Minutes (5-255)
Q32
Select Cancel Display (0 to 1)
Q33
Select Cross Sensor 47-48 (0 to 1)
Q34
Enter Cross Sensor Timeout, in Seconds (10-120)
Q35
Select Abort Window Dialer Delay (0 to 2)
Q36
Select Burglary Bell Cutoff (0 to 4)
Q37
Select Fire Bell Cutoff (0 to 4)
Q38
Enter Time to Detect AC Loss, in Minutes (1-30)
Q39
Select Random AC Loss Report Time (0 to 1)
Q40
Enter CS #2 Phone Number (0-25 digits)
Q43
Enter Installer Code (4 digits)
Q44
Select Lock Installer Programming (0 to 2)
Q45
Select Lock Default Programming (0 to 2)
Q46
Select Trouble Doesn't Sound at Night (0 to 1) *
Q47
Select Troubles Resound After Holdoff (0 to 7)
Q48
Enter Download CSID (6 digits)
Q49
Select Programming Mode Entry Reports to CS (0 to 1)
Q50
Select Trouble Reports to CS (0 to 1)
Q51
Select Manual Bypass Reports to CS (0 to 1)
Q52
Select AC Loss Reports to CS (0 to 1)
Q53
Select System Low Battery Reports to CS (0 to 1)
Q54
Select RF Low Battery Reports to CS (0 to 1)
Q55
Select Opening Reports to CS (0 to 1)
Q56
Select Closing Reports to CS (0 to 1)
Q57
Select Alarm Restore Reports to CS (0 to 1)
Q58
Select Trouble Restore Reports to CS (0 to 1)
Q59
Select Bypass Restore Reports to CS (0 to 1)
Q60
Select AC Restore Reports to CS (0 to 1)
Q61
Select System Low Battery Restore Reports to CS (0 to 1)
Q62
Select RF Low Battery Restore Reports to CS (0 to 1)
Q63
Select Phone Fail Detect (0 to 1)
Q64
Select Smart Test Reports (0 to 1)
Q65
Select RF Jam Causes Trouble (0 to 1)
Q66
Select Daylight Saving (0 to 1)
Q67
Select Daylight Saving Start Month (01 to 12)
Q68
Select Daylight Saving Start Sunday (1 to 7)
Q69
Select Daylight Saving End Month (01 to 12)
Q70
Select Daylight Saving End Sunday (1 to 7)
Q71
Select System Tamper Causes Trouble (0 to 1)
Q72
Select Quick Bypass (0 to 1)
Q73
Select Disarming Keyfob After Alarm Alert (0 to 1)
Q74
Select Keyfob Arm/Disarm Confirmation (0 to 1)
Q75
Select Auto Unbypass for Manual Bypass (0 to 1)
Q76
Select Force Bypass Reports (0 to 1)
Q77
Select Event Log (0 to 3)
Q78
Select Output (00-12)
Q79
Select Z-Wave Feature (0 to 3)
Q80
Select Z-Wave Switches Feature (0 to 1)
Q81
Select Z-Wave Thermostats Feature (0 to 1)
Q82
Select Z-Wave Door Locks Feature (0 to 1)
Q83
Select Temperature Display Units (0 to 1)
Select date and time format (0 to 2)
Default Setting
(0) Disabled
7 Days
30 Minutes
(1) Enabled
(1) Enabled
(1) Enabled ‡
(1) Enabled ‡
(1) Enabled
30 Days
5 Minutes‡
(1) Enabled‡
(0) Disabled
10 Seconds
(1) 30 Seconds‡
(0) 4 Minutes
(0) 4 Minutes
10 Minutes
(1) Enabled
No Default
1561
(0) Disabled
(0) Default All
(1) Enabled
(0) Disabled
000000
(0) Disabled
(1) Enabled
(0) Disabled
(1) Enabled
(1) Enabled
(1) Enabled
(0) Disabled
(0) Disabled
(0) Disabled
(1) Enabled
(0) Disabled
(1) Enabled
(1) Enabled
(1) Enabled
(0) Disabled
(0) Disabled
(0) Disabled
(1) Enabled
(03) March
(2) 2nd
(11) November
(1) 1st
(1) Enabled
(0) Disabled
(0) Disabled
(0) Disabled
(1) Enabled
(0) Disabled
(3) All Events
(11) Follows Internal Sounder Alarm‡
(3) Enabled with Local Rules
(1) Enabled
(1) Enabled
(1) Enabled
(0) Degrees Fahrenheit
(0) MM-DD-YY H:MM AM/PM
Copyright © 2018 Nortek Security & Control
Programming Question Table
30
Need help?
Do you have a question about the 2GIG e Series and is the answer not in the manual?