GC2e Wireless Security System | Installation and Programming Guide
Q85: Master User Access to Z-Wave Toolbox
(0-1)
DEFAULT: (0) Disabled
The Z-Wave Toolbox menu can be set to require the use of the
master user code or the installer code . By default, the installer code
is required for users to access the Z-Wave Toolbox.
The default setting (0) Disabled requires users to enter the
installer code to access the Z-Wave Toolbox menu and all of its
features, including the Advanced Toolbox .
To require the use of the master user code or the installer
code to access the Z-Wave Toolbox menu, select (1) Enabled .
NOTE: When (1) Enabled, the Installer code will still be required to
access the Advanced Toolbox menu . This prevents end users from
adding or removing Z-Wave devices.

Q86: Disable Siren After Two-Way Audio (0-1)

DEFAULT: (0) Disabled
This setting enhances system operation in personal emergency
applications and also provides the dealer with the option of the
siren sounding until the bell cut off or to the end of a two-way-
voice session .
The default setting (0) Disabled will cause the siren to resume
after two-way audio (if the bell cut off timer has not expired).
(1) Enabled will cause the siren to shut off after a two-way
audio session .
Q87: Keyfob/Remote Arming Mode on System
Not Ready (0-2)
DEFAULT: (0) Auto Bypass with Zone Participation on Restore
This setting controls how the system will react when there are open
sensors and the system is armed remotely .
The default setting (0) Disabled will automatically bypass all
sensors that are open when the system is armed remotely . If a
sensor restores while the system is armed, the sensor's bypass
will be removed, and the sensor will be ready to trigger an
alarm .
To automatically bypass all sensors that are open when the
system is armed remotely, and keep all bypasses in place
during the arming cycle, even if a sensor restores, select (1)
Auto‐Bypass .
To prevent arming remotely when any sensor is open, select
(2) Arm Only When Ready .
Q89: Allow Backlight Always On (Demo Mode)
(0-1)
NOTE: May cause ghost/image retention.
DEFAULT: (0) Disabled
When set to (1) Enabled the customer can program the "always on"
option for backlight programming. Due to a small percentage of
image "ghosting" on the panel (because the backlight never goes
off), this question was been created but has been defaulted to (0)
Disabled .

Q90: Energy Feature (0 to 1)

DEFAULT: (0) Disabled and Hidden
Select (1) Disabled but Visible to show but not activate the energy
features. You can also select (2) Enabled to turn the energy feature
ON .

Q91: Radio Modem Supplier

DEFAULT: (0) No Radio Modem Supplier
NOTE: If you enable Q44: Select Lock Installer Programming,
you will not be able to change this setting.
NOTE: For compliance with UL 1610, Q91: Select Radio Modem
Supplier (0 to 5) must be set to (1) Radio Modem Supplier 1.
Select the option that corresponds to the appropriate supplier.
Options include:
Option
(0) No Radio Modem Supplier
(1) Radio Modem Supplier 1
(2) Radio Modem Supplier 2
(3) Radio Modem Supplier 3
(4) Radio Modem Supplier 4
(5) Radio Modem Supplier 5
(6) Radio Modem Supplier 6

Q92: Select Network Device (0 to 1)

DEFAULT: (0) None
When enabled, the (1) Go!Bridge option provides the installer
with the following questions to program the Go!Bridge IP
Communicator settings into the Control Panel
Q: Network Device ID (read only)
Tap Learn . Then go to the Go!Bridge device and tap the Learn
button. For details, see the Go!Bridge IP Communicator
Installation Instructions.
Q: Select Configuration Source
DEFAULT: (0) DHCP
Select between (1) Static or (2) DHCP (Dynamic Host
Configuration Protocol). The default setting is (0) DHCP and is
the most common selection. The other option is (1) Static and
requires entry of a Device IP Address, Gateway IP Address, and
Subnet Mask .
Q: Enter Device IP Address
DEFAULT: 000.000.000.000
NOTE: This question only requires an answer if you selected
(1) Static in Q: Select Configuration Source.
Use the numeric keypad to enter the IP Address for the
Go!Bridge IP Communicator .
Q: Enter the Gateway IP Address
DEFAULT: 000.000.000.000
NOTE: This question only requires an answer if you selected
(1) Static in Q: Select Configuration Source.
Use the numeric keypad to enter the IP Address for the access
point to the external network . Typically, this is the IP Address of
the local network router .
Q: Enter the Subnet Mask
DEFAULT: 000.000.000.000
NOTE: This question only requires an answer if you selected
(1) Static in Q: Select Configuration Source.
Use the numeric keypad to enter the IP Address for the subnet
mask for the network .
Copyright © 2018 Nortek Security & Control
Control Panel Programming
Supplier
This is the default setting.
Alarm.com
SecureNet
57