Q75: Auto Unbypass For Manual Bypass (0-1); Q76: Force Bypass Reports (0-1); Q77: Event Log (0-3); Q79: Z-Wave Feature (0-3) - Nortek Security & Control 2GIG e Series Installation And Programming Manual

Wireless security system
Hide thumbs Also See for 2GIG e Series:
Table of Contents

Advertisement

GC2e Wireless Security System | Installation and Programming Guide

Q75: Auto UnBypass for Manual Bypass (0-1)

DEFAULT: (1) Enabled
Violated (open) sensors can be manually bypassed by the user
through the User Toolbox or force bypassed at the time of arming.
Force bypassed sensors automatically have their bypasses removed
when the system is disarmed .
Manually bypassed sensors can have their bypass automatically
removed at disarming or have their bypasses remain in place .
The default setting (1) Enabled automatically removes
bypasses from manually bypassed sensors when the system is
disarmed .
To have manually bypassed sensors remain bypassed when
the system is disarmed, select (0) Disabled .

Q76: Force Bypass Reports (0-1)

DEFAULT: (0) Disabled
The system can report which sensors have been force bypassed by
the user when the system is armed . Forced bypassed sensors are
always recorded in the event log, regardless of the setting of this
programming question.
The default setting (0) Disabled prevents reporting forced
bypassed sensors .
To report forced bypassed sensors, select (1) Enabled .

Q77: Event Log (0-3)

DEFAULT: (3) All Events
To control the amount of event log entries, the events that get
recorded into the system's event log can be selected by type . This
setting filters the events that populate the event log.
The default setting (3) All Events records all events in the
event log .
To choose different options, select one of these filters:
Event Log Filters
(0) Disabled (no events logged)
(1) All Events Except Open, Closing, and Bypass
(2) All Events Except Open and Closing
(3) All Events

Q79: Z-Wave Feature (0-3)

DEFAULT: (3)
(3) Enabled on Panel; Rules Disabled, Remote Access
Enabled
The Z-Wave home services feature can be enabled or disabled with
various remote control access options.
The default setting (3) Enabled on Panel; Rules Disabled,
Remote Access Enabled displays the Services button, but will
show a message that the feature is currently disabled and the
user should call the installer .
To hide the Services button, select (0) Disabled and Hidden .
To show the Services button but disable it from use, select (1)
Disabled but Visible .
To show the Services button and disable off- site remote
control, select (2) Enabled on Panel, Remote Access Disabled .

Q80: Z-Wave Switches Feature (0 to 1)

DEFAULT: (1) Enabled
Display of the Home Service's Switches button can be enabled
or disabled .
NOTE: This programming question only functions if Q79: Z-
Wave Feature is set to (2) or (3) .
The default setting (1) Enabled shows the Switches button.
To hide the Switches button, select (0) Disabled .

Q81: Z-Wave Thermostats Feature (0 to 1)

DEFAULT: (1) Enabled
Show or hide the Home Service's Thermostats button on the
Control Panel .
NOTE: This programming question only functions if Q79: Z-
Wave Feature is set to (2) or (3) .
The default setting (1) Enabled shows the Thermostats
button.
To hide the Thermostats button, select (0) Disabled .

Q82: Z-Wave Door Locks Feature (0-1)

DEFAULT: (1) Enabled
Display of the Home Service's Door Locks button can be enabled
or disabled. This programming question only functions if the
Z-Wave feature enable question Q79: Z‐ Wave Feature is set to
(2) or (3) .
The default setting (1) Enabled shows the Door Locks
button.
To hide the Door Locks button, select (0) Disabled .

Q83: Select Temperature Display Units (0-1)

DEFAULT: (0) Degrees
Fahrenheit
The Home Service's Z-Wave thermostat display screens can
show the temperature in degrees Fahrenheit or degrees Celsius .
NOTE: This programming question only functions if Q79: Z-
Wave Feature is set to (2) or (3) and Q81: Z-Wave Thermostats
Feature is set to (1) Enabled .
The default setting is (0) Degrees Fahrenheit .
To change the setting, select (1) Celsius .
NOTE: The setting you select here also changes the display units
shown on the weather forecast on the Control Panel's Home
screen .

Q84: Services Require Master Code (0 to 1)

DEFAULT: (0) Disabled
The Services button can be configured to require the use of the
master user code to access Services .
The default setting (0) Disabled overrides the requirement
to enter a master user code to access the Services menu .
To require the use of the master user code to access the
Services menu, select (1) Enabled.
When enabled then the master user code is required to access
the Services and the Z-Wave device configurations. This keeps
unauthorized users from being able to change Z- Wave settings,
such as temperature, lights and locks .
Copyright © 2018 Nortek Security & Control