GC2e Wireless Security System | Installation and Programming Guide
Installer Programming
Account Registration
Register the account to enroll the Control Panel with the remote
service provider's Central Station.
Typically, the account registration data is created with the service
installation contract and then stored in a database managed by
the Central Station. The data includes items such as the customer
name, address, and the Central Station telephone number, and the
account number assigned to the Control Panel .
If you will be installing the 2GIG Go!Bridge IP Communicator,
additional registration information is required. For details, see
the Installation Instructions included with the Go!Bridge IP
Communicator .
Wireless (RF) Sensor Programming
The Control Panel can be programmed with up to 60 RF sensors
of different types. In addition to the 60 multi- purpose RF sensors,
you can also program eight (8) RF remote control key fobs and four
(4) RF remote control keypads into the system .
RF sensors # 01‐48 and #63‐74 report as wireless zones 01‐ 60.
Programming questions for RF sensor programming include:
•
Q1: Select RF Sensor Number . Select sensor number 01-48 or
63-74.
• Q: Select RF Sensor # Type. Select (01) Exit/Entry 1, (02)
Exit/Entry 2, (03) Perimeter, and so on. For options, see
"Zone Numbering" on page
• Q: Select RF Sensor # Equipment Type . Some sensor types
ask for the equipment type, others do not . See
RF Sensor # Equipment Type" on page
32 .
"Q: Select
40 .
•
Q: Select RF Sensor # Equipment Code. Select the four (4)-
digit equipment code for the sensor model . See
Codes" on page
37 .
•
Q: Enter RF Sensor # Other Equipment Code . If you select
(0000) Other in the previous question, you must enter this
code .
•
Q: Enter RF Sensor # Serial # . Enter the serial number
(typically a label on the sensor or its packaging) or tap Shift
then Learn on the panel . Then trip the sensor to transmit
the serial number to the panel .
•
Q: Select RF Sensor # Equipment Age . Specify whether the
sensor is (0) New or (1) Existing .
•
Q: Select RF Sensor # Loop Number . Specify the
appropriate loop number(s) for the sensor .
Sensor # Loop Number (1 to 3)" on page
•
Q: Select RF Sensor # Dialer Delay . Specify whether to use
delayed or instant digital communicator reports for the
sensor. The delay time is set on the Dialer Abort screen.
•
Q: Construct RF Sensor # Voice Descriptor . Specify the
name assigned to the sensor that is announced if this
feature is programmed .
•
Q: Select RF Sensor # Reports . Specify (0) Disabled or (1)
Enabled whether or not RF sensors trigger a report to the
Central Station.
•
Q: Select RF Sensor # Supervised . Specify whether or not
the Control Panel checks for status reports from the sensor .
•