Selecting The Photo Diode Polarity (Pdpol); Programming The Optical Power (Popt) - THORLABS ITC8 Series Operation Manual

Combined module for pro8000, pro8000-4, pro800 systems
Table of Contents

Advertisement

_________________________________________________________________________________

3.2.15 Selecting the photo diode polarity (PDPOL)

Programming:
":PDPOL AG"
":PDPOL CG"
Reading:
":PDPOL?"

3.2.16 Programming the optical power (POPT)

Programming:
":POPT:SET <NR3>"
Reading:
":POPT:SET?"
":POPT:ACT?"
":POPT:MIN?"
":POPT:MAX?"
":POPT:MIN_W?"
":POPT:MAX_W?"
":POPT:MIN_R?"
":POPT:MAX_R?"
_____________________________________________________________________________________________________
© 2010
Thorlabs
Selects anode on ground
Selects cathode on ground
Reads the monitor diode polarity
[:PDPOL AG<LF>]
[:PDPOL CG<LF>]
Programs the optical power
Reads the set optical power
[:POPT:SET <NR3><LF>]
Reads the actual optical power
[:POPT:ACT <NR3><LF>]
Reads the minimum allowed set optical power
[:POPT:MIN <NR3><LF>]
Reads the maximum allowed set optical power
[:POPT:MAX <NR3><LF>]
Reads the optical power for P
[:POPT:MIN_W <NR3><LF>]
Reads the optical power for P
[:POPT:MAX_W <NR3><LF>]
Reads the optical power for P
[:POPT:MIN_R <NR3><LF>]
Reads the optical power for P
[:POPT:MAX_R <NR3><LF>]
Commands
– DAC = 0000
LD
– DAC = FFFF
LD
–ADC = 0000
LD
–ADC = FFFF
LD
51