2 Grippers

2.3.1 Operating requirements

2.3 Installation

2.3.1 Operating requirements
Protection standard
Option combination
All gripper combinations
Ambient temperature
Description
Gripper during operation
Gripper during transporta-
tion and storage
Air input
The nominal operating pressure is 6 bar. Considering the working pressure of air
tube in arm, in normal operation the gripper is recommended to be supplied with
5-6 bar air input. Before the air input, ensure that the input air is filtered and clean.
Relative humidity
Description
Complete gripper during operation, transportation and
storage
68
Standard/Option
Standard
Standard
© Copyright 20192020 ABB. All rights reserved.
Protection standard IEC529
IP30
Temperature
+ 5°C (41°F) to + 40°C (104°F)
- 10°C (14°F) to + 55°C (131°F)
Relative humidity
85% at constant temperature
(gaseous only)
Product specification - IRB 14050