The oven only operates at 220 to 240 Volts single phase. It must be earthed.
Before connection to the power supply, make sure that the rating of the circuit breakers and fuses it sufficient for the normal
power consumption of the appliance and that the power cable has a 2.5 mm² section.
CONNECTING YOUR APPLIANCE :
The power supply cable* of the oven can be connected to a socket (minimum 16 amps) or an oven outlet.
In the latter case, a double-pole switch with a gap between the contacts of at least 3 mm, should be installed in the circuit
to conform with safety regulations.
In both cases, the green and yellow wire of the power supply cable should be connected to earth.
NB : Do not forget that the appliance may require an S.A.V. operation. Also, position the socket so that it can be connected to
the oven when it is out of the cavity.
* Power supply cable : if the power supply cable has to be changed, the job should be carried out by our after-sales Service
personnel or by a similarly qualified person.
WE CANNOT BE HELD RESPONSIBLE FOR ANY ACCIDENT RESULTING
34 -
FROM INCORRECT OR NON-EXISTENT EARTHING.
Fixed power
supply
Oven outlet
220/240-Volt meter between
phases or between
phase and neutral
Contact breaker
minimum rating:
20 Amps
Power supplied
16-Amp fuse
through socket
Earth
Oven fitted with
16-Amp socket
cable