Repair
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
Installation of
The Display must be in place and must be connected. The NBP Board must have been
Inverter Board
removed. If the Main Board is in place, the IR Shield must have been removed.
Step 1.
Step 2.
Step 3.
Step 4.
5-40
Troubleshooting, Service and Repair
Figure 5-11 Removing the Inverter Shield
Using the T-10 screwdriver, remove the two 4mm T-10 screws holding the Inverter
Shield to the Chassis.
Lift and slide out the Inverter Shield.
Inverter-to-Main Cable
Figure 5-12 Inverter Board Connections
If necessary, detach the Inverter-to-Main Cable connector from the Inverter Board
by using fingernails on the two edges of the connector to work it loose. Do not pull
on the wires or use a screwdriver.
Caution—
Take extra care, as excessive force can damage the connector.
Detach the Inverter-to-Display connector from the Inverter Board.
Remove the two 4mm T-6 screws holding the Inverter Board to the Chassis. Lift off
the board.
Place the Inverter Board on the Chassis with the large connector on the right. The
screw holes in the board should match the screw mounts on the Chassis. If the large
square aperture is farthest from you and the ribbon cable is on the left, the Inverter
Board will be on the side closest you and to the right.
Fasten the Inverter Board to the Chassis with the two 4mm T-6 screws.
On the right side, gently press the connector of the Inverter-to-Display Cable into
the large connector of the Inverter Board.
On the left side of the Inverter Board, press the Inverter-to-Main Cable into the
keyed connector.