Terminal Connections - Omron SX-F Instruction Manual

High power direct torque control inverters
Table of Contents

Advertisement

Terminal connections

5-2
Terminal connections
Table 16 Control signals
Terminal
Name
Outputs
1
+10 V
6
-10 V
7
Common
11
+24 V
12
Common
15
Common
Digital inputs
8
DigIn 1
9
DigIn 2
10
DigIn 3
16
DigIn 4
17
DigIn 5
18
DigIn 6
19
DigIn 7
22
DigIn 8
Digital outputs
20
DigOut 1
21
DigOut 2
Analogue inputs
2
AnIn 1
3
AnIn 2
4
AnIn 3
5
AnIn 4
Analogue outputs
13
AnOut1
14
AnOut2
Relay outputs
31
N/C 1
32
COM 1
33
N/O 1
41
N/C 2
42
COM 2
43
N/O 2
42
The terminal strip for connecting the control signals is accessible after open-
ing the front panel.
The table describes the default functions for the signals. The inputs and out-
puts are programmable for other functions as described in chapter SECTION
11 page 83. For signal specifications refer to chapter SECTION 14 page 277.
Note The maximum total combined current for outputs 11, 20 and 21 is 100mA.
+10 VDC supply voltage
-10 VDC supply voltage
Signal ground
+24 VDC supply voltage
Signal ground
Signal ground
RunL (reverse)
RunR (forward)
Off
Off
Off
Off
Off
RESET
Ready
Brake
Process Ref
Off
Off
Off
Min speed to max speed
0 to max torque
Relay 1 output
Trip, active when the VSD is in a TRIP condition.
Relay 2 output
Run, active when the VSD is started.
Function (Default)
Section 5-2