Omron SX-F Instruction Manual page 79

High power direct torque control inverters
Table of Contents

Advertisement

The control panel
Section 9-2
Sub menus
213
212
100
211
511
Toggle loop
221
341
222
331
Sub menus
228
Fig. 57 Default toggle loop
Indication of menus in toggle loop
T
Menus included in the toggle loop are indicated with a
in area B in the dis-
play.
Loc/Rem function
The Loc/Rem function of this key is disabled as default. Enable the function in
menu [2171] and/or [2172].
With the function Loc/Rem you can change between local and remote control
of the VSD from the control panel. The function Loc/Rem can also be
changed via the DigIn, see menu Digital inputs [520]
Change control mode
1. Press the Loc/Rem key for five seconds, until Local? or Remote? is dis-
played.
2. Confirm with Enter.
3. Cancel with Esc.
Local mode
Local mode is used for temporary operation. When switched to LOCAL opera-
tion, the VSD is controlled via the defined Local operation mode, i.e. [2171]
and [2172]. The actual status of the VSD will not change, e.g. Run/Stop condi-
tions and the actual speed will remain exactly the same. When the VSD is set
L
to Local operation, the display will show
in area B in the display.
71