GSMBR / iGSMBR Installation and Setup Guide
PROMPTS
Strt Prog Mode?
1
Y/N_
Enter Password
2
Program Device?
3
Y/N_
Create Password?
4
Y/N_
Change Password?
5
Y/N_
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
Y/N_
Device Mode
9
(ECP)_
3-12
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
[Y], [N]
Enters programming mode.
[0-9, A-F, N,
If a password has been previously assigned, this
S, T, X, Y]
prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
[Y], [N]
To begin programming the module, press [Y] and
go to Prompt 9: "Device Mode."
To create a password if none has been assigned,
press [N] and go to Prompt 4: Create Password.
To change an existing password, press [N] and
go to Prompt 5: "Change Password."
[Y], [N]
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt
appears after pressing [N] at the "Program
Device?" prompt.
If a password is desired, press [Y] and go to
Prompt 6: "Enter Password."
[Y], [N]
If a password has already been assigned, this
prompt appears after pressing [N] at the
"Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key
when prompted for the new password and its
confirmation.
[0-9, A-F, N,
This prompt is displayed if [Y] was pressed in
S, T, X, Y]
Prompt 4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
[0-9, A-F, N,
Re-enter the password as confirmation.
S, T, X, Y]
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
[Y], [N]
Exits program mode.
Press [N] to go back to Prompt 3.
[ESC]
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode
paragraph in this section.
• ECP
Press the [Space] key to scroll through the modes
of operation.
• Zone Trig.
Press [ENTER] to select mode.
• 4204 Emu
• Two 4204s
See Table 3 for ECP mode programming.