Honeywell AlarmNet GSMBR Installation And Setup Manual page 35

Communications module
Table of Contents

Advertisement

PROMPTS
Restore Zn5 Y/N
53
(Y)_
Delay Zn5 (secs)
54
(00)_
Rpt Zn5 ONLY if
55
Armed (N)_
Enable Zn6 Y/N
56
(N)_
Zn6 Trigger Type
57
(V+)_
Invert Zn6 Y/N
58
(N)_
Restore Zn6 Y/N
59
(Y)_
Delay Zn6 (secs)
60
(00)_
Rpt Zn6 ONLY if
61
Armed (N)_
Enable Zn7 Y/N
62
(N)_
Zn7 Trigger Type
63
(V+)_
Invert Zn7 Y/N
64
(N)_
Restore Zn7 Y/N
65
(Y)_
Delay Zn7 (secs)
66
(00)_
Rpt Zn7 ONLY if
67
Armed (N)_
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
2-
4204
only
2-
4204
only
2-
4204
only
4204
only
4204
only
4204
only
4204
only
4204
only
4204
only
OPTIONS
[Y], [N]
Enables restore reporting for zone 5.
[01-15]
Defines the reporting delay in seconds for zone 5.
[00] = no
delay
[Y], [N]
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
[Y], [N]
Enables alarm reporting for zone 6.
If [N], skip to Prompt 62: "Enable Zn7."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [Space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
6 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 6.
[01-15]
Defines the reporting delay in seconds for zone 6.
[00] = no
delay
Reports alarms on zone 6 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 6.
[Y], [N]
Enables alarm reporting for zone 7.
If [N], skip to Prompt 70: "Use DHCP."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [Space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
7 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 7.
Zone Trigger mode: This prompt will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
[01-15]
Defines the reporting delay in seconds for zone 7.
Zone Trigger mode: This prompt will only be
[00] = no
displayed if zone 7 is not used as the conditional
delay
(arming) trigger zone.
[Y], [N]
Reports alarms on zone 7 ONLY if the
conditional zone (zone 4 in 4204 mode; zone 8 in
2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode: If any zone is programmed to
"Report Only if Armed," or if tamper is enabled,
skip to Prompt 70: "Use DHCP."
Section 3: Programming
DESCRIPTION
3-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alarmnet igsmbr

Table of Contents