9 Columbia Way Baulkham Hills, NSW 2153 PH 02-9894-1444 • FAX 02-9894-4193 www.notifier.com ASY-01-044 - NIM Product Installation Sheet 1.00 28/06/2012 Rev: DOC-03-061 ECN12-0032 1 Product Overview This Installation sheet describes how to mount and connect: A Network Interface Module (NIM) to a Fire Panel The Network Interface Module stores data received from the Networks Cards.
Page 2
2. Remove the 4 M3 x 8mm screws connecting the PSI mounting bracket to the Loop Interface Module (LIM) Figure 2-1: Removal of the M3 x 30mm Spacers, and the M3 x 20mm Spacers NOTE: Do not remove the M3 Screws connecting the PSI Mounting Bracket to the PSI board.
Page 3
3. Replace the existing M3 x 20mm Spacers and the M3 x 30mm Spacers with 4 M3 x 25mm Spacers (#11171) Figure 2-2: Mounting NIM to LIM with M3 x 25mm Spacers 4. Replace the 40 - Way Ribbon Cable connected to the LIM ‘IN’ Port with the 100mm 40 - Way Ribbon Cable (#10202) - see Connection Schematic.
Page 4
10. Position the PSI board assembly over the M3 x 25mm Spacers (#11171) and the M3 x 15mm Spacers (#11828) 11. Secure the PSI mounting bracket to the bottom Spacers with 2 M3 x 8mm Screws (#2316) 12. Screw the top part of the PSI board to the top spacers with 2 M3 x 8mm Screws (#2316) Figure 2-3: Mounting PSI board to NIM...
Components Part No. Description Screw Sems - Pan Philip Zinc, M3 X 8mm w/Flat Small 2316 S/Washer 10200 Cable-Assembly, C24 - 40 Way X 440mm 10202 Cable-Assembly, C26 - 40 Way X 100mm 10206 Cable-Assembly, C30 - 3 Way X 330mm 11171 M3 tapped spacer x 25mm - M/F, hexagonal, nickel finish 11628...